Congratulation on your new Blu-Link!

...

Warning  
Incorrectly connecting positive and negative battery terminals may cause immediate damage to the device, which is not covered by the warranty, and can lead to fire. 

Warning

Warning
Device for use in places where the presence of children is not possible.

Warning

Warning
Persons under 18 years of age ought not stay unattended near the device during the installation or servicing of a device installed in an ASG replica.

Warning

Warning
Persons under 18 years of age ought not stay unattended near the device installed in an ASG replica ready for use.

Warning

Warning
Persons under 18 years of age are not allowed to install or commission the device in an ASG replica.

Warning

Warning
Persons under 18 years of age are not allowed to service this device.

Caution
Prevent the device from contact with conductive materials, such as dust, liquid or metal powder.

...

  1. The color of LED reflects on the problem type:

    1. Yellow indicates a warning

    2. Red indicates a problem

  2. Number of blinks determines what exactly the problem is (for reference, read DTC explanations presented later on in this guide)

DTC explanations

  • grafika - flaga w kolorze i z liczba plus strzałki wyjaśniające

  • dodać za liczbą mignięć znak “x” np. 2x

  • przemyśleć bardziej obrazowe oznaczanie liczby mignięć, np. warfet, 4 błyśnięcia:

Notice
If you use an ETU connected to Blu-Link, check also the ETU DTC. Blu-Link is designed to withstand higher power load and lower voltage than ETU, so in most cases, the ETU protection turns on earlier and the Blu-Link does not detect the problem.

LED

WHAT HAPPENED

POSSIBLE REASON

WHAT TO DO

ULL – User load limit was exceeded.

  1. The load limit is set too low, according to the AEG configuration.

  2. Other possible reasons the same as in OCP or SCP.

  1. Modify adjustable smart fuse settings.

  2. Follow the OCP or SCP guidelines.

  3. Contact us at support@gatee.eu

OCP – Blu-Link has detected a too high current. The overcurrent protection was activated.

  1. Motor is damaged.

  2. Motor or gearbox is jammed.

  3. Motor connections short circuit.

  1. Replace the motor.

  2. Unjam the motor or gearbox.

  3. Check and fix the motor wires insulation.

SCP – Blu-Link has detected a current over 270A. The short circuit protection was activated.

  1. Motor is damaged.

  2. Motor or gearbox is jammed.

  3. Motor connections short circuit.

  1. Replace the motor.

  2. Unjam the motor or gearbox.

  3. Check and fix the motor wires insulation.

OTP – Blu-Link temperature is too high. Over temperature protection was activated.

  1. Outside temperature is too high in correlation with the demanding AEGExcessively high outside temperature in combination with a tuned replica.

  2. Frequent short circuits and Blu-Link electrical overloads.

  1. Wait until the temperature drops.

UVP1 – Battery protection was activated.

The battery is discharged.

Charge the battery.

UVP2 – The voltage dropped below level critical for Blu-Link to work properly.

1. The battery is discharged.

2. The battery is worn out and has too high internal resistance.

3. Inadequate battery type for given AEG configuration.

4. Too much electrical resistance between Blu-Link and the battery.

5. Motor is too powerful for the battery connected.

6. Motor connections short circuit.

7. Motor is jammed.

8. Motor is damaged.

  1. Charge the battery.

  2. Replace the battery.

  3. Use a battery of a greater capacity or voltage.

  4. Do not use any adapters.

  5. Use standard or high-torque motors instead of high-speed ones.

  6. Check and fix the motor wires insulation.

  7. Unjam the motor.

  8. Replace the motor.

 

UVP3 – Protection against over-discharge of the battery. Battery protection activated immediately after the battery was connected.

  1. Number of cells differs from the number set in the GCS.

  2. The battery is discharged.

  1. Set the same number of cells in GCS as in the battery.

  2. Charge the battery up.

...