General
...
Click here 1️⃣ to go to Restore Default Settings 2️⃣ – restores default settings for the various functionalities. Trigger and selector calibration as well as statistics remain unchanged and 3️⃣ Restore Factory Settings – (hard reset) restores all default settings, resets your statistics, and clears adaptation data.
4️⃣ Cycle Detection – switches ON or OFF the optical gear sensor. Cycle Detection OFF can be compared to an emergency mode for problems with the gear sensor. Most TITAN features will be disabled, but you can still shoot in AUTO.
5️⃣ Thanks to the gear Gear sensor, TITAN precisely detects in which position the cycle should finish. Therefore, even the shortest Trigger action produces at least one full cycle.
6️⃣ A set of preferences referring to the active profile and switching between Profiles.
7️⃣ Battery protection – modern LiPo and LiFe batteries are very sensitive to over-dischargeoverdischarge. The microprocessor monitors the battery voltage constantly. When the voltage drops down to a critical level, it will not allow firing.
Battery cell – when the battery voltage drops to the specified level (in relation to one cell), the motor will vibrate. You can set: OFF, 3.1 V, 3.2 V, 3.2V 3 V or 3.4V 4 V per cell for LiPo battery and batteries and 2.6 V, 2.7 V, 2.7V 8 V or 2.9V per cell for LiFe batterybatteries. 30-Round Limit – an AEG can continuously fire max. 30 BBs. To fire more BBs, you must release the Trigger before. This is
8️⃣ Series Safety Limit – enables to set a predefined number of BBs fired in a single series. It can be used as a protection against Trigger jam. Important: in In case of emergency, you can also stop firing the series by switching the Selector position.
8️⃣
9️⃣ Gear ratio Ratio - to make the activate PRE-COCKING work with the highest level of precision you should define the gears type in your AEG. Available types: STANDARD, HIGH TORQUE, HIGH SPEEDNormal Speed, Low Speed, High Speed, DSG, 19-TOOTHTooth.
Typical gear ratio settings (excluding DSG and 19-tooth):
HIGH TORQUE: <15 RPS
STANDARD: 15-25 RPS
HIGH SPEED: >25 RPS
If overspin issue occurs, you should switch the gear type to the next level (e.g. STANDARD to HIGH TORQUE).
...
Tip |
---|
Note |
Tip |
---|
Note |
Trigger
...
2️⃣ Pre-cocking – allows for initial spring compression, which speeds up the Trigger response significantly:
AUTO MODE – the spring is automatically compressed after each shot
Trigger MODE – slow Trigger action compresses the spring, and fast Trigger action fires the shot
Please note: using PRE-COCKING increases wear and tear on the gearbox.
...
Burst mode:
FULL – every, even the shortest Trigger action fires the pre-determined number of
rounds
Trigger – releasing the Trigger while firing stops the burst sequence.
Burst – allows you to set how many BBs will be fired
3️⃣ ROF stabilization:
ON – ROF Control uses PWM (Pulse Width Modulation) to decrease ROF. Thanks to this, gearbox works smoothly what decreases wear and tear of AEG internal parts. The percentage value determines the PWM duty cycle and it does not reflect ROF decrease.
OFF – ROF Control adds breaks between shots to decrease ROF. It gives you more realistic experience. This option set to 50% will significantly reduce the rate of fire.
ROF control – enables a reduction in a gun’s rate of fire. You use stronger LiPo batteries, and still have a ROF just like in a real gun.
Sniper delay – lets you to set delay between each SEMI shots to simulate the delay from reload or recoil. You can set 0.5s, 1s, 2s or 3s delay. By choosing ‘VIB’ option, you can enable vibration which will inform you when the gun is ready to fire again.
Equalizer (dynamic Trigger point):
OFF - to 4️⃣ You don't need to fully release the trigger to fire the next shot. This option is really useful when the trigger sensitivity level is very high. Choose between two types of Equalizer.
1LVL, 2LVL and MANUAL are especially useful when trigger sensitivity level is very high, so you do not need to fully release the trigger while firing quickly:
TITAN V2
OFF – to fire the next shot, you need to
...
release the trigger until it reaches the selected trigger sensitivity level.
2LVL – to fire the next shot, just release the trigger until it moves over two adjoining sensors.
1LVL – to fire the next shot, just release the trigger until it moves over an adjoining sensor.
TITAN V3 & TITAN V2 NGRS
OFF – to fire the next shot, you need to release the trigger until it reaches the selected trigger sensitivity level.
2LVL – to fire next shot, just release the trigger so it changes the position by ~40% of trigger movement.
1LVL – to fire next shot, just release the trigger so it changes the position by ~20% of trigger movement.
MANUAL – thanks to EXPERT firmware, you can adjust the percentage of trigger movement exactly as you prefer. This option is not available in TITAN V2 because of sensors type.
5️⃣ Sniper delay – lets you to set delay between each SEMI shots to simulate the delay from reload or recoil. You can set 0.5s, 1s, 2s or 3s delay. By choosing ‘VIB’ option, you can enable vibration which will inform you when the gun is ready to fire again.
We designed the Sensors TAB in order to let you choose the Trigger sensitivity or Trigger mode that is the best for you. Thanks to live view, you do not need to mechanically adjust your Trigger. Simply choose the value and check if it suits you.
...