LED

WHAT HAPPENED

POSSIBLE REASON

WHAT TO DO

ULL – User load limit exceeded

  • The load limit has been set too low in relation to AEG configuration

  • Other possible reasons are the same as in the case of OCP or SCP

  • Modify the adjustable smart fuse settings

  • Follow the OCP or SCP guidelines

  • Contact us at support@gatee.eu

OCP – Blu-Link has detected excessive current activating overcurrent protection

  • Motor damaged

  • Motor or gearbox jammed

  • Motor connection short circuit

  • Replace the motor

  • Unjam the motor or gearbox

  • Check and fix motor wire insulation

SCP – Blu-Link has detected a current over 270 A activating short circuit protection

  • Damaged motor

  • Jammed motor or gearbox

  • Motor connection short circuit

  • Replace the motor

  • Unjam the motor or gearbox

  • Check and fix motor wire insulation

OTP – Blu-Link temperature is too high activating over temperature protection

  • Excessively high outside temperature in combination with a tuned replica

  • Frequent short circuits and Blu-Link electrical overloads

Wait until Blu-Link temperature drops

UVP1 – Battery protection was activated.

Discharged battery

Charge the battery

UVP2 – The voltage has dropped below the critical level for Blu-Link to work properly

  • The battery is discharged.

  • The battery is worn out and has excessively high internal resistance

  • Inadequate battery type for current AEG configuration.

  • Too much electrical resistance between Blu-Link and the battery

  • The motor is too powerful for the battery connected

  • Motor connection short circuit

  • Jammed motor

  • Damaged motor

  • Charge the battery

  • Replace the battery

  • Use a battery of a greater capacity or voltage

  • Do not use any adaptors

  • Use standard or high-torque motors instead of high-speed ones

  • Check and fix the motor wire insulation

  • Unjam the motor

  • Replace the motor

 

UVP3 – Protection against battery overdischarge activated immediately after the battery was connected

  • The number of cells differs from the number set in GCS

  • The Discharged battery is discharged

  • Set the same number of cells in GCS as in the battery

  • Charge the battery

...

Tip

Note
It is a good practice to clear the DTC DTCs in GCS before each skirmish.

Tip

Note
Blu-Link is compatible with TITAN V2, TITAN V3, TITAN V2 NGRS, ASTER V2, ASTER V3, STATUS and as well as future GATE products.

Bluetooth® Trademark Attribution

...

GATE Enterprise sp. z o.o. sp. k. hereby declares declare under our sole responsibility that GATE Blu-Link is in conformity with the essential requirements of the following directives: 2012/19/UE, 2014/53/UE, 2011/65/UE.

...

Please read this Legal Notice before operating your device and keep it for future reference.
This document contains important terms and conditions with respect to your device. By using of this device, you accept those terms and conditions.

...

GATE Enterprise sp. z o.o. sp. k. is are not liable for any damages, injuries or accidents of any kind resulting from the use of this product or airsoft gun with the product installed, including (but not limited to) incidental or intentional damages to airsoft gun, airsoft gun parts, batteries and gearbox internals.

...

GATE Enterprise sp. z o.o. sp. k. takes take no responsibility regarding compliance of the product with the requirements of any law, rule or airsoft restrictions pertaining thereto.

...

GATE Enterprise sp. z o.o. sp. k. warrants warrant that its their product is free from manufacturing and material defects at the date of purchase and for a non-extendable period of two (2) years from the date of purchase. This Limited Warranty is conditioned upon proper use of the product by Purchaser.

...