The most common mistakes:
1. Washer
...
Issue
User's fault:
Placing theplacing washers in wrong order
.Result:
Shortshort circuit and permanent damage to
theTITAN
.How to detect?
Correct order:
...
2. Trigger sensors damageSensor Damage
User's fault:
Pullingpulling the trigger when the gearbox is open
.Result:
Tearingtorn off trigger sensors
.
while
TITAN will not be able to detect all 5 trigger sensitivities evenif using a standard trigger (please note that in the case of speed triggers TITAN
alsocannot detect all trigger sensitivities
and it doesn’teither, which does not mean that sensors are damaged).
How to detect?
Triggermissing trigger sensors (receivers)
are missing.
...
...
3. Cables damageCable Damage
User's fault:
Incorrectincorrect cable routing
.Result:
Damaging or total tearing thedamaged or torn off wires by motor gear
How to detect?
Insulation isdamaged
.insulation
...
...
4. Capacitor damageDamage
User's fault:
Mountingmounting TITAN V2 in an ICS gearbox without necessary modifications
Result:
Gearbox latch is damaging or total tearingthe gearbox latch has damaged or torn the yellow capacitor
How to detect?
Yellowthe yellow capacitor is missing or damaged
...
5. Gear sensor damageSensor Damage
User's fault:
Toovery low shimming of sector gear
Result:
Tearingtorn off gear sensor
.How to detect?
Gearmissing gear sensor
is missing.
...
...
Less frequently encountered:
6. Fire selector sensor damage Fire Selector Sensor Damage
User's fault:
Incorrectincorrect bottom board placement in gearbox shell
Result:
Tearingtorn off
fire selectorFire Selector sensor
.How to detect?
Oneone of the trigger sensors
ismissing
7. Motor connector damage
User's fault:
Usingusing too much force during motor connector bending, bending connector to wrong side
...
...
Result:
Brakingbroken motor connector
How to detect?
Motormotor connector
isbroken in half
8. Reverse Reverse polarity
User's fault:
Pluggingplugging a battery
tointo the unit in incorrect order (a negative wire with a positive wire and a positive wire with a negative wire)
Result:
Destroyingdestroying the main parts of the board
How to detect?
Unittheunit is not responding,
wholethe entire board is
burnedburnt
...
9. Wire damage Damage (caused Caused by triggerTrigger)
User's fault:
Incorrectincorrect wire placement in gearbox shell
Result:
Tearingtorn wire insulation
How to detect?
Wiretornwire insulation
is tearedclose to the trigger
10. Short circuit caused by damaging cables insulation Short Circuit Caused by Damaging Cable Insulation
User's fault: Cutting both positive and negative
wirewires with body of the replica
Result: Insulation damage, short circuit
How to detect?
BurnedBurnt wires from a cut place
11. Repairs or structural modification Structural Modification of any TITAN part, including re-wiring Part (including rewiring and component replacement)
User's fault:
Interferenceinterference in the
constructionstructure of the unit
Result:
Automaticautomatic warranty loss
of the warrantyHow to detect?
Visiblevisible changes
likesuch as different wire color
...
Cases when warranty should be accepted:
- Constantly occurring errors from
recurring E01 to E06
and, E13, E14, and E15 errors
- Total
total absence of reaction from the unit without visible damage
- No
no connection with
theUSB-Link and/or
programming cardTactical Programming Card even if the unit is working properly without any visible damage (no programming option)
- Continuous occurrence
recurrence of error E07 combined with no cycle detection (after very accurate troubleshooting)
Info |
---|
In case of any doubts please contact oursupportSupport at:support@gatee.eutel. +48 12 210 05 23 |