User's fault: placing washers in wrong order
Result: short circuit and permanent damage to TITAN
How to detect?
Correct order:
...
2. Trigger Sensor Damage
...
User's fault: incorrect cable routing
Result: damaged or torn off wires by motor gear
How to detect? damaged insulation
...
4. Capacitor Damage
User's fault: mounting TITAN V2 in an ICS gearbox without necessary modifications
Result: the gearbox latch has damaged or torn the yellow capacitor
How to detect? the yellow capacitor is missing or damaged
...
5. Gear Sensor Damage
User's fault: very low shimming of sector gear shimming
Result: torn off gear sensor
How to detect? missing gear sensor
...
Less frequently encountered:
6. Fire Selector Sensor Damage
...
User's fault: using too much force during motor connector bending, bending connector to connectors wrong sideway
...
Result: broken motor connector
How to detect? motor connector broken in half
...
User's fault: accidentallycutting both positive and negative wires with the body of the replica
Result: Insulation damage, short circuit
How to detect? Burnt visibly cut wires
11. Repairs or Structural Modification of any TITAN Part (including rewiring and component replacement)
User's fault: interference in the structure of the unit
Result: automatic warranty loss
How to detect? visible changes such as different wire color
...
Cases when warranty should be accepted:
recurring E01 to E06, E13, E14, and E15 errors
total absence of reaction from the unit without visible damage
no connection with USB-Link and/or Tactical Programming Card even if the unit is working properly without any visible damage (no programming option)
recurrence of error E07 combined with no cycle detection (after very accurate detailed troubleshooting)
Info |
---|