  • User's fault: placing washers in wrong order

  • Result: short circuit and permanent damage to TITAN

  • How to detect?:

   
 

Correct order:

...


2. Trigger Sensor Damage

  • User's fault: pulling the trigger when the gearbox is open

  • Result: torn off trigger sensors
    TITAN will not be able to detect all 5 trigger sensitivities even if using a standard trigger (please note that in the case of speed triggers TITAN cannot detect all trigger sensitivities either, which does not mean that sensors are damaged).

  • How to detect?: missing trigger sensors (receivers)

...

  • User's fault: incorrect cable routing

  • Result: damaged or torn off wires by motor gear

  • How to detect?: damaged insulation

...

4. Capacitor Damage

  • User's fault: mounting TITAN V2 in an ICS gearbox without necessary modifications

  • Result: the gearbox latch has damaged or torn the yellow capacitor

  • How to detect?: yellow capacitor is missing or damaged

...

  • User's fault: very low sector gear shimming

  • Result: torn off gear sensor

  • How to detect?: missing gear sensor

...


Less frequently encountered:

...

  • User's fault: incorrect bottom board placement in gearbox shell

  • Result: torn off Fire Selector sensor

  • How to detect? : one of the trigger sensors missing

...

  • User's fault: using too much force during motor connector bending, bending connectors wrong way

    Image RemovedImage Added
  • Result: broken motor connector

  • How to detect? : motor connector broken in half

...

  • User's fault: plugging a battery into the unit in incorrect order (a negative wire with a positive wire and a positive wire with a negative wire)

  • Result: destroying the main parts of the board

  • How to detect? : theunit is not responding, the entire board is burnt

...

  • User's fault: incorrect wire placement in gearbox shell

  • Result: torn wire insulation

  • How to detect? : tornwire insulation close to the trigger

...

  • User's fault: accidentallycutting both positive and negative wires with the body of the replica

  • Result: Insulation damage, short circuit

  • How to detect? : visibly cut wires

11. Repairs or Structural Modification of any TITAN Part (including rewiring and component replacement)

  • User's fault: interference in the structure of the unit

  • Result: automatic warranty loss

  • How to detect? : visible changes such as different wire color

...