Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Click here for USB-Link Troubleshooting: https://gateee.atlassian.net/wiki/spaces/GHC/pages/335806634/Information+for+Use+In4U+TTN#USB-Link-Troubleshooting

3. Now you can control TITAN via GCS.

...

1️⃣ Use Trigger Preferences to calibrate your trigger. You can only make changes once you've connected your replica with an ETU inside. You will learn more about TITAN trigger calibration here: Information for Use (In4U) [TTN]

...

2️⃣ Pre-Cocking allows for initial spring compression, which speeds up Trigger response significantly:
Auto – the spring is automatically compressed after each shot. In Auto you can also set Boost, which determines the strength of spring compression.
If overspin occurs, set Gear Ratio to High Speed.

...

5️⃣ Sniper Delay lets you to set delay between each SEMI shot to simulate the delay from reload or recoil. You can set it between 0.01 and 5 s. By choosing the Manual with Vibration option, you can enable a vibration which will inform you when the gun is ready to fire again.

...

Selector

...

1️⃣ Selector mode Mode – allows you to choose how your replica will behave behaves in each Selector position:
Depending on Firmware Edition, you can set 1 of the 7 options in each Selector position.

...

SAFE – the replica will not fire when the Trigger is pulled
SEMI – one pull of the Trigger will result in only one shot
BURST – one pull of the Trigger enables you to shoot a pre-determined number of BBs, which is very useful in MILSIM MilSim and when using low-caps
AUTO – pulling the Trigger causes fires an uninterrupted* series of shots until the Trigger is released
*the series can be limited by the Round Limit.

Besides the SAFE, SEMI, AUTO, and BURST modes, there is the BINARY Trigger — a single BB is fired when the Trigger is pressed and another one when the Trigger is released; SEMI Ramping – quickly squeezing the Trigger turns on AUTO mode; BURST/AUTO – pulling the Trigger quickly sets BURST and holding it down sets AUTO.

2️⃣ Burst Mode – sets the exact number of BBs fired in a single BURST. Interruptible allows you to stop the BURST by releasing the Trigger. Full will fire the exact number of BBs without stopping even if the Trigger is released during the BURST. In case of emergency, you can stop the series by switching the Selector position.

...

Magazine

1️⃣ Magazine Mode – allows to switch on Magazine Simulation and Bolt Catch in NGRS gearboxes.

2️⃣ Magazine Capacity – depending on the Firmware Edition, allows you to set magazine capacity simulation from 1 BB up to 250 BBs. Please note that in all gearboxes except NGRS, all the BBs fired are counted until the counter reaches the set capacity, even if the real magazine is replaced in the middle of magazine simulation. In NGRS gearboxes, thanks to the magazine sensor, if the real magazine is replaced during magazine simulation, the counter is reset to the full simulated magazine capacity. In all cases, you are informed about an empty simulated magazine with vibrations — a high one and two low ones.

3️⃣ Reload Time – depending on the Firmware Edition, enables you to set the exact time of simulated magazine replacement from 0.1 s up to 10.0 s. During this time you will not be able to shoot.

4️⃣ Low Ammo Warning – enables you to set the exact number of BBs fired before low ammo warning vibrations – a high one and a low one.

...

Alerts

...

1️⃣ Vibration Notifications – allows you to select the type of notifications you will be informed about with vibrations.

...

Telemetry

Telemetry contains main information about your replica’s performance. You can simply clear each value by clicking the Reset button. You can also independently reset BB1 and BB2 counter.
TITAN gives you the option to check:
ROF - Minimum, Average, Maximum
Trigger response - Minimum, Average, Maximum
Module temperature - Minimum, At this moment, Maximum
Motor current - Average AUTO, Average SEMI, Maximum Peak
Battery voltage - Minimum, Last, Maximum
Number of fired BBs - BB1, BB2, TOTAL

...

This TAB will help you to troubleshoot your replica in case of any issue. If you need additional help, you can contact our Support Center using  “SEND REPORT” button, or save the report using  “SAVE TO FILE” button.

...


If an error occurs, it will be  highlighted and  described. In such a case, we suggest to follow  ”WHAT TO DO” instructions in the first place.

Instructions

 

...

Powiązane artykuły

...

.

...

hiddentrue

...