The table presents DTCs along with their possible reasons and solutions.

...

 

Nombre del DTC

name

DTC 

Number of vibrations and type

Error description (What happened)

Possible reason
(Why it happened)

Possible solution
(What to do)

Under Voltage Protection

Número de vibraciones y tipo

Descripción del error (Qué ha pasado)

Posible razón (Por qué ha ocurrido)

Posible razón (Por qué ha ocurrido)

Protección de bajo voltaje 1

UVP1

1/

High

Protection against Battery Over-Discharge (Battery Protection) Activated

  1. Discharged battery

  1. Charge battery

Under Voltage Protection

Alta

Protección contra la sobredescarga de la batería (protección de la batería) activada

  1. Batería descargada

  1. Cargue batería

Protección contra bajo voltaje 2

UVP2

2/

High

The voltage has dropped below critical level for TITAN to work properly

  • Discharged battery

  • The battery is worn out and there is excessive internal resistance

  • Inadequate battery type for the current AEG configuration

  • Excessive electrical resistance between TITAN and the battery

  • Motor too strong for the connected battery

  • Motor connection short circuit

  • Motor is jammed

  • Motor is damaged

  • Charge battery

  • Replace battery

  • Use a battery with more capacity or higher voltage

  • We recommend using a battery with a Deans-T connector; if you need to use an adapter, check the quality

  • Use standard or high-torque motors instead of high-speed ones

  • Check and fix motor wire insulation

  • Unjam the motor

  • Replace the motor

  • Motor Disc

    Alta

    El voltaje ha caído por debajo del nivel crítico para que TITAN funcione correctamente

    1. Batería descargada

    2. La batería está desgastada y hay una resistencia interna excesiva

    3. Tipo de batería inadecuado para la configuración actual del AEG

    4. Resistencia eléctrica excesiva entre TITAN y la batería

    5. Motor demasiado potente para la batería conectada

    6. Cortocircuito en la conexión del motor

    7. El motor está atascado

    8. El motor está dañado

    1. Cargue batería

    2. Sustituya la batería

    3. Utilice una batería con más capacidad o mayor voltaje

    4. Se recomienda utilizar una batería con conector Deans-T; si necesita utilizar un adaptador, compruebe la calidad

    5. Utilice motores estándar o de alto par en lugar de los de alta velocidad

    6. Compruebe y arregle el aislamiento de los cables del motor

    7. Desatasque el motor

    8. Sustituya el motor

    Motor desconectado

    MOTOR DISC

    4/

    High

    Alta

    TITAN

    did not detect the

    no ha detectado el motor

    The motor is not connected

  • The brushes are worn out

  • The motor is damaged

    1. Check wiring and motor connectors; connect the motor

    2. Replace the brushes

    3. Replace the motor

    Gear Not Detected
    1. El motor no está conectado

    2. Las escobillas están desgastadas

    3. El motor está dañado

    1. Compruebe el cableado y los conectores del motor; conecte el motor

    2. Sustituya las escobillas

    3. Sustituya el motor

    No se detecta el engranaje

    GND

    1/

    Low

    Baja

    TITAN

    did not detect the sector gear
  • Excessive sector gear shimming

  • Dirty sector gear sensor

  • Jammed sector
    gear

  • Damaged sector gear sensor

  • Damaged motor

    1. Remove the shims from underneath the sector gear

    2. Clean sector gear sensor; inspect the sensor using GCS; alternatively set Cycle detection to OFF

    3. Check the condition of the gears

    4. Set Cycle Detection to OFF (to maintain minimum and contact us at support@gatee.eu

    5. Replace the motor

    Over Current Protection

    OCP

    3/Low

    TITAN has detected excessive current. Over current protection has been activated.

    1. Motor connection short circuit

    2. Motor or gearbox jammed

    3. Motor damaged

    1. Check and fix motor wire insulation

    2. Unjam the motor or gearbox

    3. Replace motor

    Short Circuit Protection

    SCP

    4/Low

    TITAN has detected current over 220 A. Short circuit protection has been activated.

    1. Motor connection short circuit

    2. Motor or gearbox jammed

    3. Motor damaged

    1. Check and fix motor wire insulation

    2. Unjam the motor or gearbox

    3. Replace motor

    Over Temperature Protection

    OTP

    5/Low

    TITAN temperature is too high. Over temperature protection has been activated.

    1. The outside temperature is too high in relation to the requirements of your AEG

    2. Frequent short circuits and TITAN electrical overloads

    1. Wait until temperature drops

    Self-Test Failure

    STF

    2/Low-High

    The device failed on self-test

    1. Device Internal error

    1. Contact us at support@gatee.eu.

    Other errors

     

    2/High-Low

     

     

    Connect TITAN to GCS and check for

    no ha detectado el engranaje de sector

    1. Calce excesivo del engranaje de sector

    2. Sensor de engranaje de sector sucio

    3. Engranaje de sector atascado

    4. Sensor del engranaje sectorial dañado

    5. Motor dañado

    1. Retire los calzos de la parte inferior del engranaje sectorial

    2. Limpie el sensor del engranaje de sector; inspeccione el sensor utilizando el GCS; alternativamente, ajuste la detección del ciclo en Apagado.

    3. Comprobar el estado de los engranajes

    4. Ponga la detección de ciclo en Apagado (para mantener el mínimo y póngase en contacto con nosotros en support@gatee.eu

    5. Sustituya el motor

    Protección contra sobrecorriente

    OCP

    3/Baja

    TITAN ha detectado una corriente excesiva – se ha activado la protección contra sobrecorriente

    1. Cortocircuito en la conexión del motor

    2. Motor o caja de cambios atascado

    3. Motor dañado

    1. Compruebe y arregle el aislamiento del cable del motor

    2. Desatasque el motor o la caja de cambios

    3. Sustituya el motor

    Protección contra cortocircuitos

    SCP

    4/Baja

    TITAN ha detectado una corriente superior a 220 A – se ha activado la protección contra cortocircuitos

    1. Cortocircuito en la conexión del motor

    2. Motor o caja de cambios atascados

    3. Motor dañado

    1. Compruebe y arregle el aislamiento del cable del motor

    2. Desatasque el motor o la caja de cambios

    3. Sustituya el motor

    Protección contra sobretemperatura

    OTP

    5/Baja

    La temperatura del TITAN es demasiado alta. Se ha activado la protección contra la sobretemperatura.

    1. La temperatura exterior es demasiado alta en relación con los requisitos de su AEG

    2. Frecuentes cortocircuitos y sobrecargas eléctricas de TITAN

    1. Espere a que la temperatura baje

    Fallo en el autodiagnóstico

    STF

    2/Baja-Alta

    El dispositivo ha fallado en el autotest

    1. Error interno del dispositivo

    1. Póngase en contacto con nosotros en support@gatee.eu

    Otros errores

     

    2/Alta-Baja

     

     

    Conecte TITAN al GCS y compruebe si hay DTCs

    TITAN V2

    TITAN V2 dispone de los siguientes sensores:
    1 sensor de engranaje del sector
    2 sensores del selector
    5 sensores de gatillo

    ...

    Instalación

    Por favor, lea la guía de instalación a continuación antes de proceder.

    ...

    TITAN V3 has the following optical sensors:

    1 sector gear sensor
    1 selector sensor
    1 proximity trigger sensor

    ...

    Installation

    Please read the Installation Guide below before proceeding.

    ...

    TITAN V2 NGRS has the following sensors:

    2 gear sensors
    1 selector sensor
    1 trigger sensor
    1 bolt catch sensor

    ...

    Installation