Tip |
---|
Note
|
Technical Specifications
Rated Voltage | 4,75-17 VDC |
---|---|
Rated Current | 30 A |
Current Consumption without Load | 280 uA |
Maximum Current Consumption without Load | 45 mA (for 17 VDC) |
Dimensions (Length x Width x Thickness) | 54,5 mm x 19,9 mm x 9 mm |
Finished Product Weight | 9,65 g |
Operating Temperature Range | min. -15° C, max. +50° C |
Relative Humidity | ≤ 80% |
How to Use Blu-Link
...
Tip |
---|
Note |
...
Open the stock cover
Remove the stock buffer tube end cap
Plug in your AEG/ETU into the Blu-Link OUTPUT connector
Plug the AEG battery into the Blu-Link INPUT connector
Insert Blu-Link and the battery into the stock buffer tube
Replace the stock cover
Replace the stock buffer tube
Enjoy airsofting
Troubleshooting
...
LED | What happened: | What to do: |
---|---|---|
1 s on start | Self-test completed successfully |
|
Blu-Link has been connected correctly |
| |
BLINKING for 120 s | Blu-Link is ready for Bluetooth connection® | Connect Blu-Link to GCS |
Self-test failed, Bluetooth® connection is not possible |
| |
BLINKING |
|
|
for 120 s | Blu-Link is connected correctly via Blutooth® | Enjoy using Blu-Link |
Blu-Link firmware update in progress |
| |
|
| |
|
| |
BLINKING | Overload, DTC displayed: 2 – ULL, 3 – OCP, 4 – SCP, 5 – OTP | Read what to do in the next section or connect Blu-Link to GCS and check the Diagnostics tab |
BLINKING | Excessively low voltage, DTC displayed: 1 – UVP1, 2 – UVP2, 3 – UVP3 | Read what to do in the next section or connect Blu-Link to GCS and check the Diagnostics tab |
DTC Codes
Diagnostic Trouble Codes (DTC) indicate basic malfunctions and problems with your battery, AEG, ETU or Blu-Link. You are notified about them by a LED blinking for 120 s after the problem occurs. The Blu-Link DTCs can later be read and cleared in the Diagnostics tab in GCS.
...
Tip |
---|
Note |
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
ULL – User load limit exceeded |
|
| |
OCP – Blu-Link has detected excessive current activating overcurrent protection |
|
| |
SCP – Blu-Link has detected a current over 270 A activating short circuit protection |
|
| |
OTP – Blu-Link temperature is too high activating over temperature protection |
| Wait until Blu-Link temperature drops | |
UVP1 – Battery protection was activated | Battery discharged | Charge battery | |
UVP2 – The voltage dropped below critical level for Blu-Link to work properly |
|
| |
| UVP3 – Protection against battery overdischarge activated immediately after battery was connected |
|
|
Tip |
---|
Note |
...