LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|
Image RemovedImage Added | ULL – User load limit exceeded | | Modify the adjustable smart fuse settings Follow the OCP or SCP guidelines Contact us at support@gatee.eu
|
Image RemovedImage Added | OCP – Blu-Link has detected excessive current activating overcurrent protection | | |
Image RemovedImage Added | SCP – Blu-Link has detected a current over 270 A activating short circuit protection | | |
Image RemovedImage Added | OTP – Blu-Link temperature is too high activating over temperature protection | | Wait until Blu-Link temperature drops |
Image RemovedImage Added | UVP1 – Battery protection was activated | Battery discharged | Charge battery |
Image RemovedImage Added | UVP2 – The voltage dropped below critical level for Blu-Link to work properly | Battery discharged The battery is worn out and has excessively high internal resistance Inadequate battery type for current AEG configuration Too much electrical resistance between Blu-Link and the battery Motor too powerful for the battery connected
Motor connection short circuit Jammed motor Damaged motor
| Charge battery Replace battery
Use battery of greater capacity or voltage Do not use any adaptors
Use standard or high-torque motors instead of high-speed ones Check and fix motor wire insulation Unjam motor Replace motor
|
Image RemovedImage Added | UVP3 – Protection against battery overdischarge activated immediately after battery was connected | | |