If you are using an ETU connected to Blu-Link, also check the ETU DTCs. Blu-Link is designed to withstand higher power load and lower voltage than an ETU, so in most cases, ETU protection is activated earlier and Blu-Link does not detect the problem.

GCS Code (Old Code)

warning

error

Nname

Error Description

Possible reason

Possible solution

LED (Review in GCS)

UVP1

Under Voltage Protection 1

Protection against battery over-discharge (battery protection) activated

  1. Discharged battery

  2. Battery type or number of battery cells set incorrectly

  1. Charge the battery

  2. Set the correct battery type or number of battery cells

Yellow(1)

UVP2

Under Voltage Protection 2

Voltage has dropped below a critical level for your device to work properly

  1. Discharged battery

  2. The battery is worn out and there is excessive internal resistance

  3. Inadequate battery type for the current AEG configuration

  4. Excessive electrical resistance between your device and the battery

  5. Motor too strong for the connected battery

  6. Motor connection short circuit

  7. Jammed motor

  8. Damaged motor

  1. Charge the battery

  2. Replace battery

  3. Use a battery with more capacity or higher voltage

  4. We recommend using a battery with a Deans-T connector; if you need to use an adaptor, check the quality

  5. Use standard or high-torque motors instead of high-speed ones

  6. Check and fix motor wire insulation

  7. Unjam the motor

  8. Replace the motor

Yellow(2)

UVP3

Under Voltage Protection 3

Protection against battery over-discharge (battery protection) activated immediately after connecting the battery

  1. The number of cells is different from the number set in GCS

  2. Discharged battery

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery

Yellow(3)

OVP

Over Voltage Protection

Voltage exceeding a critical level for your device to work properly

  1. Connected battery type not supported by the unit

  1. Replace the battery

Red(1) + Yellow(1)

TEMP (OTP)

Over Temperature Protection

Excessive device temperature – over-temperature protection activated

  1. The outside temperature is too high in relation to the requirements of your AEG

  2. Frequent short circuits and device electrical overloads

  1. Wait until the temperature drops

Red(5)

OCP1 (E11)

Over Current Protection Type 1

Excessive current detected – overcurrent protection activated

  1. Motor connection short circuit

  2. Motor or gearbox jammed

  3. Motor damaged

  1. Check and fix motor wire insulation

  2. Unjam the motor or gearbox

  3. Replace motor

Red(3)

OCP2 (E12)

Over Current Protection Type 2

Excessive current detected – overcurrent protection activated

  1. Motor connection short circuit

  2. Motor or gearbox jammed

  3. Motor damaged

  4. Battery voltage too high for the current motor

  1. Check and fix motor wire insulation

  2. Unjam the motor or gearbox

  3. Replace motor

  4. Replace the battery

Red(3)

SELF (E14 STF)

Self-Test Failure

The device failed on self-test

  1. Device Internal Error

  2. Always activated with other Device Internal Errors

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Blue(1)

FET1 (E01 EA01 T_Drive)

Main Transistors Error

Main Transistors Error

  1. Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Blue(1)

VME1 (E03 EA03 VoltageSensor)

Voltage Measurement Error

Voltage Measurement Error

  1. Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Yellow(1)

TSE (E04 EA04 TempSensor)

Temperature Sensor Error

Temperature Sensor Error

  1. Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Yellow(1)

CSE (E05 AmpSensor)

Current Sensor Error

Current Sensor Error

  1. Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Yellow(1)

CFG (E13 EA13 Config)

Configuration Error

Configuration Error

?

  1. Restore factory settings

  2. Install the newest firmware

  3. Clear the DTC

  4. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  5. Connect your device to the battery and wait again 10s

  6. Check the DTC again – if the error persists, contact us at support@gatee.eu

Red(1) + Yellow(1)

SCP1

Short Circuit Protection 1

Blu-Link detected Current over 270 A – short-circuit protection activated

  1. Motor connection short circuit

  2. Motor or gearbox jammed

  3. Motor damaged

  1. Check and fix motor wire insulation

  2. Unjam the motor or gearbox

  3. Replace motor

Red(?)

SCP2

Short Circuit Protection 2

Blu-Link has detected a shorted female Deans-T connector in Firing Mode

  1. Motor connection short circuit

  2. Motor or gearbox jammed

  3. Motor damaged

  1. Check and fix motor wire insulation

  2. Unjam the motor or gearbox

  3. Replace motor

?

U-OCP (USER_OCP)

User Load Limit

User load limit exceeded

  1. The load limit has been set too low in relation to AEG configuration

  2. Other possible reasons are the same as in the case of OCP or SCP

  1. Modify the adjustable smart fuse settingsFollow the OCP or SCP guidelines

  2. Contact us at support@gatee.eu

Red(2)

BTDC

Bluetooth® Communication Error

Bluetooth® Communication Error

  1. Your device is too far away from Blu-Link

  2. Radio signal too weak

  1. Move your device closer to Blu-Link

?

BTE

Bluetooth® Module Failure

Bluetooth® Module Failure

Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

COMP (F_CompInm)

Comparator Error

Current Sensor Error

Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

ESC (ETU_SC)

Output Connector Short Circuit

Short circuit at the output connector or an internal error detected

A damaged external device was connected, a short circuit in the connector, an internal error


  1. Disconnect any connected external devices.

  2.  Check the condition of the connector (make sure there’s no dirt or bent parts). 

  3. Clear the DTC

  4. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  5. Connect your device to the battery and wait again 10s

  6. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

CURS (F_Cur_Source)

Internal Power Supply Error

Internal Power Supply Error

Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

COMMT (F_G1W_TX)

G1W Interface Error 1

G1W Interface Error 1

Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

COMMR (F_G1W_RX_USBL)

G1W Interface Error 2

G1W Interface Error 2

Device Internal Error

  1. Clear the DTC

  2. Unplug your device from the battery and Blu-Link/USB-Link and wait 10s

  3. Connect your device to the battery and wait again 10s

  4. Check the DTC again – if the error persists, contact us at support@gatee.eu

?

...

LED

WHAT HAPPENED

POSSIBLE REASON

WHAT TO DO

Image RemovedImage Added

ULL – User load limit exceeded

  • The load limit has been set too low in relation to AEG configuration

  • Other possible reasons are the same as in the case of OCP or SCP

  • Modify the adjustable smart fuse settings

  • Follow the OCP or SCP guidelines

  • Contact us at support@gatee.eu

OCP – Blu-Link has detected excessive current activating overcurrent protection

  • Motor damaged

  • Motor or gearbox jammed

  • Motor connection short circuit

  • Replace motor

  • Unjam motor or gearbox

  • Check and fix motor wire insulation

SCP – Blu-Link has detected a current over 270 A activating short circuit protection

  • Motor damaged

  • Motor or gearbox jammed

  • Motor connection short circuit

  • Replace motor

  • Unjam motor or gearbox

  • Check and fix motor wire insulation

OTP – Blu-Link temperature is too high activating over temperature protection

  • Excessively high outside temperature in combination with a tuned replica

  • Frequent short circuits and Blu-Link electrical overloads

Wait until Blu-Link temperature drops

UVP1 – Battery protection was activated

Battery discharged

Charge battery

UVP2 – The voltage dropped below critical level for Blu-Link to work properly

  • Battery discharged

  • The battery is worn out and has excessively high internal resistance

  • Inadequate battery type for current AEG configuration

  • Too much electrical resistance between Blu-Link and the battery

  • Motor too powerful for the battery connected

  • Motor connection short circuit

  • Jammed motor

  • Damaged motor

  • Charge battery

  • Replace battery

  • Use battery of greater capacity or voltage

  • Do not use any adaptors

  • Use standard or high-torque motors instead of high-speed ones

  • Check and fix motor wire insulation

  • Unjam motor

  • Replace motor

 

UVP3 – Protection against battery overdischarge activated immediately after battery was connected

  • The number of cells differs from the number set in GCS

  • Battery discharged

  • Set the same number of cells in GCS as in battery

  • Charge battery

...