Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Tip

Nota
Un calce excesivo del engranaje de sector puede causar una detección incorrecta del ciclo. La leva de engranajes debe interrumpir el haz del sensor.

...

Tip

Nota  Nota
En caso de dificultades para instalar o utilizar este producto:

  • ponte en contacto con nosotros https:

ASTER V2

...

Note

Precaución
Los componentes optoelectrónicos ASTER marcados en la foto de abajo son muy sensibles. Evite su daño.

...

2. Conecte ASTER al USB-Link

Tip

Nota
Si su USB-Link no puede detectar ASTER, compruebe si ocurre lo mismo con otro PC, Mac o smartphone. Si el problema persiste:

  • envíanos un correo electrónico a support@gatee.eu

  • En caso de dificultades para instalar o utilizar este producto:

    3. Ahora puede controlar ASTER a través de GCS

    ...

    DTC name

    DTC

    LED indicator color / number of blinks and vibrations / vibration type

    Error description (what happened)

    Possible reason

    (why it happened)

    Possible solution

    (what to do)

    No errors

    Green / 1 / -

    No errors detected

    Everything is fine

    Enjoy airsofting

    Under Voltage Protection 1

    UVP1

    Yellow / 1 / High

    Protection against over-discharge of the battery. Battery protection was activated.

    1. The battery is discharged

    1. Charge the battery

    Under Voltage Protection 2

    UVP2

    Yellow / 2 / High

    The voltage dropped below 1.9 V which is critical for ASTER to work properly.

    1. The battery is discharged

    2. The battery is worn out and has too high internal resistance

    3. Inadequate battery type for given AEG configuration

    4. Too much electrical resistance between ASTER and the battery

    5. Motor too strong for the connected battery

    6. Motor connections short circuit

    7. Motor is jammed

    8. Motor is damaged

    1. Charge the battery

    2. Replace the battery

    3. Use a battery with more capacity or more voltage

    4. Do not use any adapters

    5. Use standard or high-torque motors instead of high-speed

    6. Check and fix the motor wires insulation

    7. Unjam the motor

    8. Replace the motor

    Under Voltage Protection 3

    UVP3

    Yellow / 3 / High

    Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

    1. Number of cells is different than their number set in GCS

    2. The battery is discharged

    1. Set the same number of cells in GCS as in the battery

    2. Charge the battery

    Motor Disc

    MOTOR DISC

    Yellow / 4 / High

    ASTER did not detect the motor.

    1. Motor is not connected

    2. Brushes are worn out

    3. Motor is damaged

    1. Check wiring and motor connectors. Connect the motor

    2. Replace brushes

    3. Replace the motor

    Gear Not Detected

    GND

    Red / 1 / Low

    ASTER did not detect the sector gear.

    1. Too high sector gear shimming

    2. Sector gear sensor is dirty

    3. Sector gear sensor is damaged

    4. Sector gear is jammed

    5. Motor is damaged

    1. Remove shims under the sector gear

    2. Clean sector gear sensor

    3. Contact 

    aster@gatee.eu

    1. Inspect the sensors using GCS

    2. Replace the motor

    3. In case of dirty or damaged gear sensor you may

    set Cycle detection to Off

    Overload

    OVL

    Red / 2 / Low

    Too high load. The load limit was exceeded.

    1. ASTER with BASIC and ADVANCED firmware edition is dedicated for up to mid-tuned guns

    1. Use high-torque motor and gears

    2. Upgrade firmware to EXPERT

    Over Current Protection

    OCP

    Red / 3 / Low

    ASTER detected too high current. Overcurrent protection was activated.

    1. Motor is damaged

    2. Motor or gearbox is jammed

    3. Motor connections short circuit

    1. Replace the motor

    2. Unjam the motor or gearbox

    3. Check and fix the motor wires insulation

    Short Circuit Protection

    SCP

    Red / 4 / Low

    ASTER detected current over 220 A. Short circuit protection was activated.

    1. Motor is damaged

    2. Motor or gearbox is jammed

    3. Motor connections short circuit

    1. Replace the motor

    2. Unjam the motor or gearbox

    3. Check and fix the motor wires insulation

    Over Temperature Protection

    OTP

    Red / 5 / Low

    ASTER temperature is too high. Over temperature protection was activated.

    1. Outside temperature is too high in correlation with the demanding AEG

    2. Frequent short circuits and ASTER electrical overloads

    1. Wait until the temperature drops

    Self-test Failure

    STF

    Red-Blue / 2 / Low-High

    The device failed on self-test.

    1. Internal error of the device

    1. Contact 

    aster@gatee.eu

    Other error

    Red-Yellow / 2 / High-Low

    Connect ASTER with GCS and check DTC

     