GCS Code (Old Code) warning error | Nname | Error Description | Possible reason | Possible solution | LED (Review in GCS) |
---|
UVP1 | Under Voltage Protection 1 | Protection against battery over-discharge (battery protection) activated | Discharged battery Battery type or number of battery cells set incorrectly
| Charge the battery Set the correct battery type or number of battery cells
| Yellow(1) |
UVP2 | Under Voltage Protection 2 | Voltage has dropped below a critical level for your device to work properly | Discharged battery The battery is worn out and there is excessive internal resistance Inadequate battery type for the current AEG configuration Excessive electrical resistance between your device and the battery Motor too strong for the connected battery Motor connection short circuit Jammed motor Damaged motor
| Charge the battery Replace battery Use a battery with more capacity or higher voltage We recommend using a battery with a Deans-T connector; if you need to use an adaptor, check the quality Use standard or high-torque motors instead of high-speed ones Check and fix motor wire insulation Unjam the motor Replace the motor
| Yellow(2) |
UVP3 | Under Voltage Protection 3 | Protection against battery over-discharge (battery protection) activated immediately after connecting the battery | The number of cells is different from the number set in GCS Discharged battery
| Set the same number of cells in GCS as in the battery Charge the battery
| Yellow(3) |
OVP | Over Voltage Protection | Voltage exceeding a critical level for your device to work properly | Connected battery type not supported by the unit
| Replace the battery
| Red (1) + Yellow(1)+ Blue |
TEMP (OTP) | Over Temperature Protection | Excessive device temperature – over-temperature protection activated | The outside temperature is too high in relation to the requirements of your AEG Frequent short circuits and device electrical overloads
| Wait until the temperature drops
| Red(5) |
OCP1 (E11) | Over Current Protection Type 1 | Excessive current detected – overcurrent protection activated | Motor connection short circuit Motor or gearbox jammed Motor damaged
| Check and fix motor wire insulation Unjam the motor or gearbox Replace motor
| Red(3) |
OCP2 (E12) | Over Current Protection Type 2 | Excessive current detected – overcurrent protection activated | Motor connection short circuit Motor or gearbox jammed Motor damaged Battery voltage too high for the current motor
| Check and fix motor wire insulation Unjam the motor or gearbox Replace motor Replace the battery
| Red(3) |
SELF (E14 STF) | Self-Test Failure | The device failed on self-test
| Device Internal Error Always activated with other Device Internal Errors
| Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Blue(1) |
FET1 (E01 EA01 T_Drive) | Main Transistors Error | Main Transistors Error | Device Internal Error
| Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Blue(1) |
VME1 (E03 EA03 VoltageSensor) | Voltage Measurement Error | Voltage Measurement Error | Device Internal Error
| Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Yellow(1) |
TSE (E04 EA04 TempSensor) | Temperature Sensor Error | Temperature Sensor Error | Device Internal Error
| Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Yellow(1) |
CSE (E05 AmpSensor) | Current Sensor Error | Current Sensor Error | Device Internal Error
| Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Yellow(1) |
CFG (E13 EA13 Config) | Configuration Error | Configuration Error | ? | Restore factory settings Install the newest firmware Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| Red(1) + Yellow(1)brak led |
SCP1 | Short Circuit Protection 1 | Blu-Link detected Current over 270 A – short-circuit protection activated | Motor connection short circuit Motor or gearbox jammed Motor damaged
| Check and fix motor wire insulation Unjam the motor or gearbox Replace motor
| Red(?4) |
SCP2 | Short Circuit Protection 2 | Blu-Link has detected a shorted female Deans-T connector in Firing Mode | Motor connection short circuit Motor or gearbox jammed Motor damaged
| Check and fix motor wire insulation Unjam the motor or gearbox Replace motor
| ?Red(4) |
U-OCP (USER_OCP) | User Load Limit | User load limit exceeded | The load limit has been set too low in relation to AEG configuration Other possible reasons are the same as in the case of OCP or SCP
| Modify the adjustable smart fuse settingsFollow the OCP or SCP guidelines Contact us at support@gatee.eu
| Red(2) |
BTDC | Bluetooth® Communication Error | Bluetooth® Communication Error | Your device is too far away from Blu-Link Radio signal too weak
| Move your device closer to Blu-Link
| ?brak led |
BTE | Bluetooth® Module Failure | Bluetooth® Module Failure | Device Internal Error | Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?brak led |
COMP (F_CompInm) | Comparator Error | Current Sensor Error | Device Internal Error | Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?Rde(1) + Blue(1) |
ESC (ETU_SC) | Output Connector Short Circuit | Short circuit at the output connector or an internal error detected | A damaged external device was connected, a short circuit in the connector, an internal error
| Disconnect any connected external devices. Check the condition of the connector (make sure there’s no dirt or bent parts). Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?Rde(1) + Blue(1) |
CURS (F_Cur_Source) | Internal Power Supply Error | Internal Power Supply Error | Device Internal Error | Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?Rde(1) + Blue(1) |
COMMT (F_G1W_TX) | G1W Interface Error 1 | G1W Interface Error 1 | Device Internal Error | Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?Rde(1) + Blue(1) |
COMMR (F_G1W_RX_USBL) | G1W Interface Error 2 | G1W Interface Error 2 | Device Internal Error | Clear the DTC Unplug your device from the battery and Blu-Link/USB-Link and wait 10s Connect your device to the battery and wait again 10s Check the DTC again – if the error persists, contact us at support@gatee.eu
| ?Rde(1) + Blue(1) |