Table of Contents
minLevel1
maxLevel7

...

  1. Fire a shot, burst or pull the trigger while in SAFE (only if the safety lever has been removed) and do not release the trigger.

  2. Switch the selector within 2–7 s. There is a single high frequency vibration.

  3. Switch the selector in any order to change between options, which are indicated by vibrations. 

    1. 1 high frequency vibration – Profile 1

    2. 2 high frequency vibrations – Profile 2

    3. 3 high frequency vibrations – Profile 3

  4. Release the trigger to save the selected profile.

Programming

...

via USB-Link

Tip

Note
Some options in the Programming via Trigger mode may vary in the custom/OEM versions of TITAN.

Tip

Note
To run Programming via Trigger, your AEG must have a physical 3-stage selector. 

Turning on Programming Mode

  1. Switch the selector on your replica to SEMI or BURST.* If AUTO mode is selected in SEMI position, use the alternative method below.

  2. Fire a shot or burst and do not release the trigger.

  3. Hold the trigger for 7 seconds – until you hear a vibration. 

*Not possible if AUTO mode is selected in SEMI position.

...

Alternative Method

  1. Disconnect the battery

  2. Pull the trigger and do not release it

  3. Connect the battery (ignore the warning vibrations)

  4. Hold the trigger for 3 s – until you hear a vibration

You can easily change the menu level by switching the selector. Pull the trigger to quickly navigate the menu. Each time you pull the trigger, the number of accompanying vibrations changes. The table presents functions and their options programmable via trigger as well as how they are indicated by vibrations.

Tip

Note
The number of vibrations reflects the position of an option or function from the menu, e.g. if 5 BBs are selected in Full for BURST mode, you will hear 3 vibrations.

...

*To execute an action from Advanced, hold the trigger down for more than 3 seconds.
**This needs to be predefined in the GCS and is then available at trigger level. Once you disconnect the battery, the setting cannot be changed and needs to be reintroduced in GCS.
***Not available for TITAN V2 NGRS.

Selecting a Function

  1. Switch the selector to SEMI.

  2. To get to a function, pull the trigger the specified number of times (according to the table above).

Selecting an Option of a Function

  1. Switch the selector to AUTO.

  2. To get to an option of a selected function, pull the trigger the specified number of times (according to the table above).

Advanced Options

  1. Select the Advanced option.

  2. Pull and hold the trigger for more than 3 seconds.

Saving an Option

  1. To save an option, switch the selector to SEMI.

  2. The setting is saved and you are back to the functions menu.

  3. You can set the options of the other basic functions the same way.

Exiting the Programming Mode

  1. Switch the selector to SAFE.

  2. Enjoy the TITAN functions you've just set.

Activating SAFE Mode if Not Assigned

If SAFE mode is not assigned in GCS, it is possible to activate it via the selector*:

  1. Switch the selector rapidly in this sequence: SAFE → SEMI → SAFE (SAFE → AUTO → SAFE for AK-47).

  2. Now SAFE mode is activated – switch to SEMI or AUTO to deactivate it.

  3. Switching to SAFE again accesses the fire mode assigned to the SAFE position in the GCS.

*SAFE mode also applies when the selector is in SAFE while connecting the battery – switching to SEMI or AUTO deactivates it.

https://www.youtube.com/watch?v=yD-a-htaXOs

...

Tip

Note
TITAN remembers your settings, so programming always starts by informing you of the current settings.

Programming via USB-Link

Tip

Note
You can use a USB-Link to connect your TITAN to GCS for Android and Windows/macOS. To connect to GCS for iOS, you must use a Blu-Link.

Note

Caution
Prevent the USB-Link and the ends of the USB cable from contact with conductive materials, such as dust, liquid or metal powder.

Note

Caution
Do not remove the device heat shrink tube.

1. Connect the USB-Link via its Micro-USB plug to your PC, Mac or smartphone using one of the dedicated USB cables:

  • USB-A cable for PC/Mac

  • Micro-USB or USB-C cable for smartphones

Tip

Note
The micro-USB cable has the same connectors on both sides. However, it is very important to connect the USB-Link and smartphone to the appropriate ends of the cable as otherwise, it will not work. 

...

Tip

Note
If your USB-Link cannot be detected, follow the instructions displayed in GCS.

2. Connect TITAN to the USB-Link.

Tip

Note
In case you have any difficulties while installing or using this product:

3. Now you can control TITAN via GCS.

USB-Link Troubleshooting

The USB-Link has a 4-color LED indicator.

...

Restoring Factory Settings

Tip

Note
Restoring the factory settings results in resetting the default settings, erasing adaptations and statistical data.

Tip

Note
Restoring the factory settings of TITAN V3 or TITAN NGRS requires re-calibration in GCS.

You can restore Factory Settings in 3 ways:

  • Via GCS:

Go to General. Open the menu in the upper right corner and select Restore factory settings.

...

  • While in programming mode (only for TITAN V2):

  1. Turn on the programming mode as described in Programming via Trigger

  2. Switch the selector to SEMI

  3. Pull the trigger 5 times to select Advanced (6 vibrations)

  4. Switch the selector to AUTO

  5. Pull the trigger to get to Restore Factory Settings (4 vibrations)

  6. Confirm the Restore Factory Settings option by pulling the trigger for at least 3 seconds

  • While connecting the battery (only for TITAN V2):

  1. Disconnect the battery

  2. Pull the trigger

  3. While the trigger is pulled, connect the battery (ignore the warning vibrations)

  4. Hold the trigger for 10 seconds until you hear 2 vibrations confirming the reset (ignore the vibrations occurring in the meantime informing about entering the programming mode)

  5. Release the trigger

Tip

Note
The trigger must be held down throughout the entire operation – from connecting the battery until you hear the vibrations.You can use a USB-Link to connect your TITAN to GCS for Android and Windows/macOS. To connect to GCS for iOS, you must use a Blu-Link.

Note

Caution
Prevent the USB-Link and the ends of the USB cable from contact with conductive materials, such as dust, liquid or metal powder.

Note

Caution
Do not remove the device heat shrink tube.

1. Connect the USB-Link via its Micro-USB plug to your PC, Mac or smartphone using one of the dedicated USB cables:

  • USB-A cable for PC/Mac

  • Micro-USB or USB-C cable for smartphones

Tip

Note
The micro-USB cable has the same connectors on both sides. However, it is very important to connect the USB-Link and smartphone to the appropriate ends of the cable as otherwise, it will not work. 

...

Tip

Note
If your USB-Link cannot be detected, follow the instructions displayed in GCS.

2. Connect TITAN to the USB-Link.

Tip

Note
In case you have any difficulties while installing or using this product:

3. Now you can control TITAN via GCS.

USB-Link Troubleshooting

The USB-Link has a 4-color LED indicator.

...

Restoring Factory Settings

Tip

Note
Restoring the factory settings results in resetting the default settings, erasing adaptations and statistical data.

Tip

Note
Restoring the factory settings of TITAN V3 or TITAN NGRS requires re-calibration in GCS.

You can restore Factory Settings in 3 ways:

  • Via GCS:

Go to General. Open the menu in the upper right corner and select Restore factory settings.

...

Troubleshooting

Low Battery Warnings

...

TITAN V2 has the following optical sensors:
1 sector gear sensor
2 selector sensors
5 trigger sensors

...

Installation

Please read the installation guide below before proceeding.

...

TITAN V3 has the following optical sensors:

1 sector gear sensor
1 selector sensor
1 proximity trigger sensor

...

Installation

Please read the installation guide below before proceeding.

...

TITAN V2 NGRS has the following optical sensors:

2 gear sensors
1 selector sensor
1 trigger sensor
1 bolt catch sensor

...

Installation