Notice
Keep the Blu-Link box or save PIN printed on it – you will need it in case the device is damaged, lost or stolen.
Troubleshooting
Notice
Blu-Link troubleshooting during its connection is described on Troubleshooting Card included in the kit.
DTC Codes
Do troubleshooting:
(komunikaty w trakcie działania blu-linka)
To jest wersja do zredagowania, teksty są przykładowe!
LED (komunikat trwa max 2s) powtarzać cyklicznie przez 120sek z przerwami 3sek pomiedzy cyklami powtarzania komunikatow z przerwami 1 s pomiedzy bezpiecznikami | WHAT HAPPENED | WHAT TO DO |
---|
Image Added | UVP1 Protection against over-discharge of the battery. Battery protection was activated. | Charge the battery |
Image Added | UVP2 The voltage dropped below ??? V which is critical for Blu-Link to work properly. | Charge the battery
Replace the battery
Use a battery with more capacity or higher voltage
Do not use any adapters
|
Image Added | UVP3 (okrojone do 2sek) Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. | Set the same number of cells in GCS as in the battery Charge the battery
|
Image Added | OVL Too high voltage on battery. | Replace the battery
|
Image Added | OCP Blu-Link detected too high current. Over current protection was activated. | ??? |
Image Added | SCP Blu-Link detected current over 220 A. Short circuit protection was activated. | ??? |
Image Added | OTP Blu-Link temperature is too high. Over temperature protection was activated. | Wait until the temperature drops
|
Compatible with:
TITAN V2
TITAN V3
TITAN V2 NGRS
ASTER V2
ASTER V3
STATUS
...