For your safety, read the safety information below carefully before installing the device.

 

Warning
Situations that may cause injury to yourself or others.

Caution
Situations that may cause damage to your device or other equipment.

Notice
Notes, usage tips or additional information.

 

 

Warning  
Before starting the installation process, make sure your AEG is empty and there are no BBs inside. 

Warning  
Do not store or carry flammable liquids, gases or explosive materials in the same compartment as the device, its parts or accessories.  

Warning  
If Blu-Link is attached to TITAN, incorrectly connecting positive and negative battery terminals will cause immediate damage to the device or ETU, which is not covered by the warranty, and can lead to fire.

Caution
Prevent Blu-Link from contact with conductive materials, such as dust, liquid or metal powder.

Notice
Do not remove the device protective foil.

Notice
The product Warranty Form is available on our website: www.gatee.eu/warranty

Notice
In case you have any difficulties while installing or using this product:
a) email us at support@gatee.eu
b) contact us via Facebook: https://www.facebook.com/gatee
c) call (+48) 122-100-523

...

  1. Attach Blu-Link to AEG battery top side up

  2. If LED glows green, go to the next step. If not, see Blu-Link Troubleshooting Card (included in the kit)

  3. Connect battery with attached Blu-Link to AEG/ETU

  4. Place battery in the stock

  5. Enjoy using Blu-Link

Notice
Blu-Link can stay connected plugged all the time – you do not have to detach it after skirmish.

...

Diagnostic Trouble Codes (DTC) inform about basic malfunctions and problems with your AEG/ETU or Blu-Link. You are notified of them with LED blinking for 2 minutes since the problem occurs. Blu-Link DTC can be later read and cleared in DTC menu in GCS app.

How to read DTC explanations

[grafika - flaga w kolorze i z liczba plus strzałki wyjasniające]

LED

WHAT HAPPENED

WHAT TO DO

UVP1
Protection against over-discharge of the battery. Battery protection was activated.

Charge the battery

UVP2
The voltage dropped below ??? V which is critical for Blu-Link to work properly.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

[Ad. a):

  1. Charge the battery

  2. Replace the battery

  3. Use a battery with more capacity or higher voltage

  4. Do not use any adapters

  5. Use standard or high-torque motors instead of high-speed

  6. Check and fix the motor wires insulation

  7. Unjam the motor

  8. Replace the motor]

 

UVP3
Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

[Ad. a):

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery]

OVL
Too high load. The load limit was exceeded.

???

OCP
Blu-Link detected too high current. Over current protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation]

SCP
Blu-Link detected current over 240 A ???. Short circuit protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation]

OTP
Blu-Link temperature is too high. Over temperature protection was activated.

Wait until the temperature drops

...