LED

WHAT HAPPENED

WHAT TO DO

UVP1
Protection against over-discharge of the battery. Battery protection was activated.

Charge the battery

UVP2
The voltage dropped below ??? V which is critical for Blu-Link to work properly.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU.

[Ad. a):

  1. Charge the battery

  2. Replace the battery

  3. Use a battery with more capacity or higher voltage

  4. Do not use any adapters

  5. Use standard or high-torque motors instead of high-speed

  6. Check and fix the motor wires insulation

  7. Unjam the motor

  8. Replace the motor]

 

UVP3
Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU.

[Ad. a):

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery]

OVL
Too high load. The load limit was exceeded.

???

OCP
Blu-Link detected too high current. Over current protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU.

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation]

SCP
Blu-Link detected current over 240 A ???. Short circuit protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU.

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation]

OTP
Blu-Link temperature is too high. Over temperature protection was activated.

Wait until the temperature drops

...