Caution
Prevent the device from contact with conductive materials, such as dust, liquid or metal powder.

Caution
Connecting a battery with voltage over 17 V will cause permanent damage to Blu-Link, which is not covered by the warranty.

...

LED

WHAT HAPPENED

WHAT TO DO

UVP1
Protection against over-discharge of the battery. Battery protection was activated.

Charge the battery

UVP2
The voltage dropped below ??? V which is critical for Blu-Link to work properly.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

[Ad. a):

  • Charge the battery

  • Replace the battery

  • Use a battery with more capacity or higher voltage

  • Do not use any adapters

  • Use standard or high-torque motors instead of high-speed

  • Check and fix the motor wires insulation

  • Unjam the motor

  • Replace the motor]

  •  

    UVP3
    Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

    a) If you have TITAN or ASTER, check its DTC in GCS app.

    b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

    [Ad. a):

    1. Set the same number of cells in GCS as in the battery

    2. Charge the battery]

    OVL
    Too high load. The load limit was exceeded.

    ???

    OCP
    Blu-Link detected too high current. Over current protection was activated.

    a) If you have TITAN or ASTER, check its DTC in GCS app.

    b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

    [Ad. a):

    1. Replace the motor

    2. Unjam the motor or gearbox

    3. Check and fix the motor wires insulation]

    SCP
    Blu-Link detected current over 240 A ???. Short circuit protection was activated.

    a) If you have TITAN or ASTER, check its DTC in GCS app.

    b) For other ETUs – verify what happened or Otherwise, diagnose your ETU

    [Ad. a):

  • Replace the motor

  • Unjam the motor or gearbox

  • Check and fix the motor wires insulation]

    OTP
    Blu-Link temperature is too high. Over temperature protection was activated.

    Wait until the temperature drops

    ...