Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Diagnostic Trouble Codes (DTC) enable detecting basic malfunctions and problems with your AEG or Blu-Link. You are notified of these main errors with LED blinking for 2 minutes since the problem occurs. Blu-Lnik DTC can be later read and cleared in DTC menu in GCS app.

...

LED

WHAT HAPPENED

WHAT TO DO

UVP1
Protection against over-discharge of the battery. Battery protection was activated.

Charge the battery

UVP2
The voltage dropped below ??? V which is critical for Blu-Link to work properly.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) Otherwise, verify state of your ETU.

[Ad. a):

  1. Charge the battery

  2. Replace the battery

  3. Use a battery with more capacity or higher voltage

  4. Do not use any adapters

  5. Use standard or high-torque motors instead of high-speed

  6. Check and fix the motor wires insulation

  7. Unjam the motor

  8. Replace the motor]

 

UVP3
Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) Otherwise, verify state of your ETU.

[Ad. a):

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery]

OVL
Too high load. The load limit was exceeded.

???

OCP
Blu-Link detected too high current. Over current protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) Otherwise, verify state of your ETU.

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation]

SCP
Blu-Link detected current over 220 240 A ???. Short circuit protection was activated.

a) If you have TITAN or ASTER, check its DTC in GCS app.

b) Otherwise, verify state of your ETU.

[Ad. a):

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation

OTP
Blu-Link temperature is too high. Over temperature protection was activated.

Wait until the temperature drops

...