Congratulations on your Blu-Link!
It allows you to control your GATE ETU and connect it with other compatible devices wirelessly via GATE Control Station app. Moreover, Blu-Link is an additional smart fuse and wattmeter enabling to , ie.eg. , read telemetry data.
Together with GCS, you can adjust TITAN or ASTER settings and update or upgrade their firmware from devices with Android, iOS, Windows or macOS.
...
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
UVP1 - Battery protection was activated. | The battery is discharged | Charge the battery | |
UVP2 - The voltage dropped below 1.45 V which is critical for Blu-Link to work properly. | 1. The battery is discharged 2. The battery is worn out and has too high internal resistance 3. Inadequate battery type for given AEG configuration 4. Too much electrical resistance between Blu-Link and the battery 5. Motor too strong for the connected battery 6. Motor connections short circuit 7. Motor is jammed 8. Motor is damaged |
| |
| UVP3 - Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. |
|
|
OVL - The load limit was exceeded. | Send us photo and spec of that beast. | ||
OCP - Blu-Link detected too high current. Overcurrent protection was activated. |
|
| |
SCP - Blu-Link detected current over 240 A. Short circuit protection was activated. |
|
| |
OTP - Blu-Link temperature is too high. Over temperature protection was activated. | OTP
| Wait until the temperature drops. |
...