Congratulations on your Blu-Link!
...
Notice
You can use Blu-Link without ETU. It will work as smart fuse and wattmeter enabling to , ie.eg. , read telemetry data.
First connection via GCS
...
Notice
Blu-link is compatible with Bluetooth connection version 4.1 or later
Troubleshooting
...
Diagnostic Trouble Codes (DTC) inform about basic malfunctions and problems with your battery, AEG, ETU or Blu-Link. You are notified of them with LED by LED blinking for 2 minutes since the problem occurs. The Blu-Link Link’s DTC can be later read and cleared in DTC menu in GCS app.
...
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
UVP1 - Battery protection was activated. | The battery is discharged | Charge the battery | |
UVP2 - The voltage dropped below 1.45 V which is critical for Blu-Link to work properly. | 1. The battery is discharged 2. The battery is worn out and has too high internal resistance 3. Inadequate battery type for given AEG configuration 4. Too much electrical resistance between Blu-Link and the battery 5. Motor too strong for the connected battery 6. Motor connections short circuit 7. Motor is jammed 8. Motor is damaged |
| |
| UVP3 - Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. |
|
|
OVL - The load limit was exceeded. | Send us photo and spec of that beast. | ||
OCP - Blu-Link detected too high current. Overcurrent protection was activated. |
|
| |
SCP - Blu-Link detected current over 240 A. Short circuit protection was activated. |
|
| |
OTP - Blu-Link temperature is too high. Over temperature protection was activated. | OTP
| Wait until the temperature drops. |
...