Congratulations on your Blu-Link!
...
Download and install GATE Control Station:
www.gatee.eu/gcsEnable Bluetooth on your device
Plug Blu-Link to AEG battery LED side up
If LED glows green for 1 s, go to the next step. If not, check Blu-Link Troubleshooting Card (included in the kit)
Log in to the GCS app
Prepare PIN printed on Blu-Link card
Connect Blu-Link by following instructions displayed in GCS
Plug AEG/ETU into Blu-Link
Enjoy using Blu-Link
...
Notice
Blu-link is compatible with Bluetooth connection version 4.1 0 or later
Troubleshooting
Notice
Blu-Link troubleshooting during its connection is described on Troubleshooting Card included in the kit.
Insert excerpt | ||||
---|---|---|---|---|
|
DTC Codes
Diagnostic Trouble Codes (DTC) inform about basic malfunctions and problems with your battery, AEG, ETU or Blu-Link. You are notified of them by LED blinking for 2 minutes since the problem occurs. The Blu-Link’s DTC can be later read and cleared in DTC menu in GCS app.
...
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
UVP1 - Battery protection was activated. | The battery is discharged | Charge the battery | |
UVP2 - The voltage dropped below 1.5 V which is critical for Blu-Link to work properly. | 1. The battery is discharged 2. The battery is worn out and has too high internal resistance 3. Inadequate battery type for given AEG configuration 4. Too much electrical resistance between Blu-Link and the battery 5. Motor too strong for the connected battery 6. Motor connections' short circuit 7. Motor is jammed 8. Motor is damaged |
| |
| UVP3 - Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. |
|
|
OVL - The load limit was exceeded. |
| Send us photo and spec of that beast.
| |
OCP - Blu-Link detected too high current. Overcurrent protection was activated. |
|
| |
SCP - Blu-Link detected current over >270 A. Short circuit protection was activated. |
|
| |
OTP - Blu-Link temperature is too high. Over temperature protection was activated. | OTP
| Wait until the temperature drops. |
...