Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Congratulations on your Blu-Link!

It allows you to control your GATE ETU and connect it with to other compatible devices wirelessly via GATE Control Station app. Moreover, Blu-Link is an additional smart fuse and wattmeter enabling to e.g. read telemetry data.

Together with the GCS, you can adjust TITAN or ASTER settings and update or upgrade their firmware from devices with Android, iOS, Windows or macOS.

...

Caution
Connecting battery with voltage over 17 V will cause permanent damage to Blu-Link, which is not covered by the warranty.

Notice
Do not remove the device device’s protective foil.

Notice
The product Warranty Form is available on our website: www.gatee.eu/warranty

...

  1. Plug Blu-Link to AEG battery LED side up

  2. If LED glows green, go to the next step. If not, check the Blu-Link Troubleshooting Card (included in the kit)

  3. Plug AEG/ETU into Blu-Link

  4. Enjoy using Blu-Link

...

  1. Download and install GATE Control Station:
    www.gatee.eu/gcs

  2. Enable Bluetooth on your device

  3. Plug Blu-Link to AEG battery LED side up

  4. If LED glows green for 1 s, go to the next step. If not, check the Blu-Link Troubleshooting Card (included in the kit)

  5. Log in to the GCS app

  6. Prepare PIN printed on Blu-Link card

  7. Connect Blu-Link by following instructions displayed in GCS

  8. Plug AEG/ETU into Blu-Link

  9. Enjoy using Blu-Link

Notice
Keep the Blu-Link Link’s box or save PIN printed on it – you will need it in case the device is damaged, lost or stolen.

...

LED

WHAT HAPPENED

POSSIBLE REASON

WHAT TO DO

OVL - The load limit was exceeded.

  1. Too high load

  1. Contact us at support@gatee.eu

OCP - Blu-Link detected too high current. Overcurrent protection was activated.

  1. Too low current is set in smart fuse settings

  2. Motor is damaged

  3. Motor or gearbox is jammed

  4. Motor connections' short circuit

  1. Adjust smart fuse settings

  2. Replace the motor

  3. Unjam the motor or gearbox

  4. Check and fix the motor wires' insulation

SCP - Blu-Link detected current over >270 A. Short circuit protection was activated.

  1. Motor is damaged

  2. Motor or gearbox is jammed

  3. Motor connections' short circuit

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires' insulation

OTP - Blu-Link temperature is too high. Over temperature protection was activated.

OTP

  1. Outside temperature is too high in correlation with the demanding AEG

  2. Frequent short circuits and Blu-Link’s electrical overloads

Wait until the temperature drops.

UVP1 - Battery protection was activated.

The battery is discharged

Charge the battery

UVP2 - The voltage dropped below 1.5 V which is critical for Blu-Link to work properly.

1. The battery is discharged

2. The battery is worn out and has too high internal resistance

3. Inadequate battery type for given AEG configuration

4. Too much electrical resistance between Blu-Link and the battery

5. Motor too strong for the connected battery

6. Motor connections' short circuit

7. Motor is jammed

8. Motor is damaged

  1. Charge the battery

  2. Replace the battery

  3. Use a battery with more capacity or more voltage

  4. Do not use any adapters

  5. Use standard or high-torque motors instead of high-speed ones

  6. Check and fix the motor wires insulation

  7. Unjam the motor

  8. Replace the motor

 

UVP3 - Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery.

  1. Number of cells is different than their number set in GCS

  2. The battery is discharged

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery

...