Congratulations on your Blu-Link!
...
Download and install GATE Control Station:
www.gatee.eu/gcsEnable Bluetooth function on your device
Prepare Blu-Link DTC card included in the kit
Plug Blu-Link to AEG battery LED side up. Green LED should glow green for 1 second.
Read LED status and compare it with DTC card
Log in to the GCS app
Prepare PIN printed on Blu-Link’s PIN card
Connect Blu-Link by following instructions displayed in GCS
Plug AEG/ETU into Blu-Link
Enjoy using Blu-Link
...
In the event of trouble
LED color is reflecting reflects problem type:
Yellow means warning
Red means a problem
Number of vibrations determines what exactly the problem is (for reference, read DTC explanations presented later in this guide)
...
How to read DTC explanations
grafika - flaga w kolorze i z liczba plus strzałki wyjaśniające
dodać za liczbą mignięć znak “x” np. 2x
przemyśleć bardziej obrazowe oznaczanie liczby mignięć, np. warfet, 4 błyśnięcia:
Notice
If you use an ETU connected to Blu-Link, check also the ETU's DTC. The Blu-Link is designed to withstand higher power load and lower voltage than an ETU, so in most cases, an ETU protection enables earlier and the Blu-Link doesn’t notice the problem.
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
OVL - The load limit was exceeded. |
|
| |
OCP - Blu-Link detected too high current. Overcurrent protection was activated. |
|
| |
SCP - Blu-Link detected current over >270 A. Short circuit protection was activated. |
|
| |
OTP - Blu-Link temperature is too high. Over temperature protection was activated. | OTP
| Wait until the temperature drops. | |
UVP1 - Battery protection was activated. | The battery is discharged | Charge the battery | |
UVP2 - The voltage dropped below 1.5 V which is critical for Blu-Link to work properly. | 1. The battery is discharged 2. The battery is worn out and has too high internal resistance 3. Inadequate battery type for given AEG configuration 4. Too much electrical resistance between Blu-Link and the battery 5. Motor too strong for the connected battery 6. Motor connections' short circuit 7. Motor is jammed 8. Motor is damaged |
| |
| UVP3 - Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. |
|
|
...