Congratulation on your new Blu-Link!

It allows you to control your GATE ETU and connect it to other compatible devices wirelessly via GATE Control Station app. Moreover, Blu-Link is an additional smart fuse and power analyzer multifunctional wattmeter enabling to, e.g., read telemetry data.

...

Notice
You can use Blu-Link without ETU. It will work as a smart fuse and power analyzer multifunctional wattmeter enabling to, e.g., read telemetry data.

...

In the event of trouble

  1. The colour color of LED reflects on the problem type:

    1. Yellow indicates a warning

    2. Red indicates a critical problem

  2. Number of blinks determines what exactly the problem is (for reference, read DTC explanations presented later on in this guide)

DTC explanations

  • grafika - flaga w kolorze i z liczba plus strzałki wyjaśniające

  • dodać za liczbą mignięć znak “x” np. 2x

  • przemyśleć bardziej obrazowe oznaczanie liczby mignięć, np. warfet, 4 błyśnięcia:

Notice
If you use an ETU connected to Blu-Link, check also the ETU's DTC. Blu-Link is designed to withstand higher power load and lower voltage than ETU, so in most cases, an ETU protection turns on earlier and the Blu-Link does not detect the problem.

LED

WHAT HAPPENED

POSSIBLE REASON

WHAT TO DO

OVL – The load limit was exceeded.

  1. Too high load

  1. Contact us at support@gatee.eu

OCP – Blu-Link has detected a too high current. The overcurrent protection has been activated.

  1. Too low current set in the smart fuse settings

  2. Motor is damaged

  3. Motor or gearbox is jammed

  4. Motor connections short circuit

  1. Adjust smart fuse settings

  2. Replace the motor

  3. Unjam the motor or gearbox

  4. Check and fix the motor wires insulation

SCP – Blu-Link detected a current over 270 A. The short circuit protection was activated.

  1. Motor damaged

  2. Motor or gearbox jammed

  3. Motor connections short circuit

  1. Replace the motor

  2. Unjam the motor or gearbox

  3. Check and fix the motor wires insulation

OTP – Blu-Link temperature is too high. Over temperature protection was activated.

  1. Outside temperature is too high in correlation with the demanding AEG

  2. Frequent short circuits and Blu-Link electrical overloads

Wait until the temperature drops

UVP1 – Battery protection has been activated.

The battery is discharged

Charge the battery

UVP2 – The voltage dropped below 1.5 V, which is level critical for Blu-Link to work properly.

1. The battery is discharged

2. The battery is worn out and has too high internal resistance

3. Inadequate battery type for given AEG configuration

4. Too much electrical resistance between Blu-Link and the battery

5. Motor too powerful for the battery connected

6. Motor connections short circuit

7. Motor jammed

8. Motor damaged

  1. Charge the battery

  2. Replace the battery

  3. Use a battery of a greater capacity or voltage

  4. Do not use any adapters

  5. Use standard or high-torque motors instead of high-speed ones

  6. Check and fix the motor wires insulation

  7. Unjam the motor

  8. Replace the motor

 

UVP3 – Protection against over-discharge of the battery. Battery protection activated immediately after the battery was connected.

  1. Number of cells differs from the number set in the GCS

  2. The battery is discharged

  1. Set the same number of cells in GCS as in the battery

  2. Charge the battery up

...

Bluetooth Trademark Attribution (może być małą czcionką, jak przypis)

The Bluetooth® by both, the word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by GATE Enterprise sp. z o.o. sp. k. is under license. Other trademarks and trade names are those of their respective owners.

...

This device complies with Part 15 of the FCC [Federal Communications Commission] Rules. Operation is subject to the following two conditions; (1) this device may not cause a harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

...