Technical Specifications
Rated Voltage | 4,75-17 VDC |
---|---|
Rated Current | 30 A |
Current Consumption without Load | 280 uA |
Maximum Current Consumption without Load | 45 mA (for 17 VDC) |
Dimensions (Length x Width x Thickness) | 54,5 mm x 19,9 mm x 9 mm |
Finished Product Weight | 9,65 g |
Operating Temperature Range | min. -15° C, max. +50° C |
Relative Humidity | ≤ 80% |
...
Note |
---|
Caution |
Have the PIN number printed on the Blu-Link PIN card handy
Plug the AEG battery into Blu-Link INPUT, the green LED should glow for 1 s
A blinking blue LED means Blu-Link is ready to connect to GCS
Download and install GCS: www.gatee.eu/gcs
Log into GCS
Tap + in Dashboard
Enable Bluetooth® on your device
Enable the required permissions on your device (in order to search for available Blu-Link devices within Bluetooth® range); scanning for Bluetooth® devices commences automatically
Select the Blu-Link you want to connect to from the list of available devices; if your device is not found, pull to refresh or tap Refresh Scan
Enter the PIN number
Plug in your AEG/ETU into the Blu-Link OUTPUT connector
Enjoy using Blu-Link
Tip |
---|
Note |
...
Tip |
---|
Note |
Plug and Play
Plug the AEG battery into the Blu-Link INPUT connector, the green LED should glow for 1 s
Log into the GCS App any time
Tap + in Dashboard
Enable Bluetooth® on your device
Enable the required permissions on your device (in order to search for available Blu-Link devices within Bluetooth® range), scanning for Bluetooth® devices commences automatically
Select the Blu-Link you want to connect to from the list of available devices; if your device is not found, pull to refresh or tap Refresh Scan
Plug in your AEG/ETU into the Blu-Link OUTPUT connector
Enjoy using Blu-Link
Tip |
---|
Note |
Blu-Link Installation in the Replica
Open the stock cover
Remove the stock buffer tube end cap
Plug in your AEG/ETU into the Blu-Link OUTPUT connector
Plug the AEG battery into the Blu-Link INPUT connector
Insert Blu-Link and the battery into the stock buffer tube
Replace the stock cover
Replace the stock buffer tube
Enjoy airsofting
Troubleshooting
...
LED | What happened: | What to do: |
---|---|---|
1 s on start | Self-test completed successfully |
|
Blu-Link has been connected correctly |
| |
BLINKING for 120 s | Blu-Link is ready for Bluetooth connection® | Connect Blu-Link to GCS |
Self-test failed, Bluetooth® connection is not possible |
| |
BLINKING |
|
|
for 120 s | Blu-Link is connected correctly via Blutooth® | Enjoy using Blu-Link |
Blu-Link firmware update in progress |
| |
|
| |
|
| |
BLINKING | Overload, DTC displayed: 2 – ULL, 3 – OCP, 4 – SCP, 5 – OTP | Read what to do in the next section or connect Blu-Link to GCS and check the Diagnostics tab |
BLINKING | Excessively low voltage, DTC displayed: 1 – UVP1, 2 – UVP2, 3 – UVP3 | Read what to do in the next section or connect Blu-Link to GCS and check the Diagnostics tab |
...
Diagnostic Trouble Codes (DTC) indicate basic malfunctions and problems with your battery, AEG, ETU or Blu-Link. You are notified about them by a LED blinking for 120 s after the problem occurs. The Blu-Link DTCs can later be read and cleared in the Diagnostics tab in GCS.
In the Event of Trouble
The LED color reflects the problem type:
Yellow indicates a warning
Red indicates a problem
The number of blinks determines what exactly the problem is.
DTC Explanation
...
Tip |
---|
Note |
GCS Code (Old Code) warning error | Nname | Error Description | Possible reason | Possible solution | LED (Review in GCS) |
---|---|---|---|---|---|
UVP1 | Under Voltage Protection 1 | Protection against battery over-discharge (battery protection) activated |
|
| Yellow(1) |
UVP2 | Under Voltage Protection 2 | Voltage has dropped below a critical level for your device to work properly |
|
| Yellow(2) |
UVP3 | Under Voltage Protection 3 | Protection against battery over-discharge (battery protection) activated immediately after connecting the battery |
|
| Yellow(3) |
OVP | Over Voltage Protection | Voltage exceeding a critical level for your device to work properly |
|
| Red(1*) + YellowBlue(1*) |
TEMP (OTP) | Over Temperature Protection | Excessive device temperature – over-temperature protection activated |
|
| Red(5) |
OCP1 (E11) | Over Current Protection Type 1 | Excessive current detected – overcurrent protection activated |
|
| Red(3) |
OCP2 (E12) | Over Current Protection Type 2 | Excessive current detected – overcurrent protection activated |
|
| Red(3) |
SELF (E14 STF) | Self-Test Failure | The device failed on self-test |
|
| Red(1*) + Blue(1*) |
FET1 (E01 EA01 T_Drive) | Main Transistors Error | Main Transistors Error |
|
| Red(1*) + Blue(1*) |
VME1 (E03 EA03 VoltageSensor) | Voltage Measurement Error | Voltage Measurement Error |
|
| Red(1*) + YellowBlue(1*) |
TSE (E04 EA04 TempSensor) | Temperature Sensor Error | Temperature Sensor Error |
|
| Red(1*) + YellowBlue(1*) |
CSE (E05 AmpSensor) | Current Sensor Error | Current Sensor Error |
|
| Red(1*) + YellowBlue(1*) |
CFG (E13 EA13 Config) | Configuration Error | Configuration Error | ? |
| Red(1) + Yellow(1)brak led |
SCP1 | Short Circuit Protection 1 | Blu-Link detected Current over 270 A – short-circuit protection activated |
|
| Red(?4) |
SCP2 | Short Circuit Protection 2 | Blu-Link has detected a shorted female Deans-T connector in Firing Mode |
|
| ?Red(4) |
U-OCP (USER_OCP) | User Load Limit | User load limit exceeded |
|
| Red(2) |
BTDC | Bluetooth® Communication Error | Bluetooth® Communication Error |
|
| ?brak led |
BTE | Bluetooth® Module Failure | Bluetooth® Module Failure | Device Internal Error |
| ?brak led |
COMP (F_CompInm) | Comparator Error | Current Sensor Error | Device Internal Error |
| ?Red(*) + Blue(*) |
ESC (ETU_SC) | Output Connector Short Circuit | Short circuit at the output connector or an internal error detected | A damaged external device was connected, a short circuit in the connector, an internal error |
| ?Red(*) + Blue(*) |
CURS (F_Cur_Source) | Internal Power Supply Error | Internal Power Supply Error | Device Internal Error |
| ?Red(*) + Blue(*) |
COMMT (F_G1W_TX) | G1W Interface Error 1 | G1W Interface Error 1 | Device Internal Error |
| ?Red(*) + Blue(*) |
COMMR (F_G1W_RX_USBL) | G1W Interface Error 2 | G1W Interface Error 2 | Device Internal Error |
| ?Red(*) + Blue(*) |
LED | WHAT HAPPENED | POSSIBLE REASON | WHAT TO DO |
---|---|---|---|
ULL – User load limit exceeded |
|
| |
OCP – Blu-Link has detected excessive current activating overcurrent protection |
|
| |
SCP – Blu-Link has detected a current over 270 A activating short circuit protection |
|
| |
OTP – Blu-Link temperature is too high activating over temperature protection |
| Wait until Blu-Link temperature drops | |
UVP1 – Battery protection was activated | Battery discharged | Charge battery | |
UVP2 – The voltage dropped below critical level for Blu-Link to work properly |
|
| |
| UVP3 – Protection against battery overdischarge activated immediately after battery was connected |
|
|
...
GATE Enterprise sp. z o.o. sp. k. warrant that their product is free from manufacturing and material defects at the date of purchase and for a non-extendable period of two (2) years from the date of purchase. This Limited Warranty is conditioned upon proper use of the product by Purchaser.
This Limited Warranty is valid provided that the owner provides a proof of purchase and a properly completed warranty form.
This Limited Warranty does not cover: (a) defects or damage (e.g., mechanical, thermal or chemical) resulting from accident, misuse (misinterpretation of the instructions), abuse, neglect, unusual physical, electrical or electromechanical stress, water immersion, repairs or structural modification of any part of the product, or (b) the product that has its serial number removed or made illegible; (c) defects or damage from improper operation, maintenance or installation; (d) installation of the products.
Requests for warranty are processed as soon as possible, not exceeding 7 (seven) working days. The company’s obligation under this Limited Warranty shall be limited to providing replacement of part(s) only.
Product Disposal Instructions
...