GCS can be used on PCWindows/MacOS/Android/iOS devices.

...

  • update and upgrade TITAN firmware

  • change all TITAN settings

  • calibrate the Trigger and Selector

  • set Trigger sensitivity

  • check the status state of your TITAN sensors

  • check the Telemetry data of your gun (Rate of Fire, Trigger response etc.)

  • check Diagnostic Trouble Codes (DTCs)

  • contact GATE Support Center (via error report, messenger or phone)

...

Click here for USB-Link Troubleshooting: https://gateee.atlassian.net/wiki/spaces/GHC/pages/335806634/Information+for+Use+In4U+TTN#USB-Link-Troubleshooting

3. Now you can control TITAN via GCS.

Below you will see screenshots with various types of ETUs, so what you see in your GCS may differ, and some options might not be available.

Registration

We recommend creating your own profile. Though this is not obligatory, it comes in handy when contacting GATE Support.

...

Once you log in, you’re taken to the Dashboard, which contains . When you plug in your USB-Link and ETU connection starts automatically.

...

Once you have connected all the devices you need, your Dashboard looks like this:

...

1️⃣ information about your operating system information and the GCS App version and your operating system info as well as 2️⃣ the board version,

2️⃣ the serial number of other connected devices (e.g. USB-Link: the serial number and the firmware version)

3️⃣ information about the connected ETU: firmware edition, serial number, and firmware version of the connected TITAN. 3️⃣ Here ; here you can update your unit to the latest firmware version and/or 4️⃣ upgrade the edition to ADVANCED or EXPERT.

Click 4️⃣ click the mail icon to in the upper right corner to go to messages 5️⃣.

...

Use the radio buttons on the left 6️⃣ to toggle between other options. See the sections below for more information.

...

If you’re logged in, in the top left corner you will see your nick 7️⃣ 6️⃣ next to the GATE logo. Click it and you’re taken to the Preferences screen, where you can check and/or update your account info and privacy settings, submit feedback, get help, read the End User Licence Agreement (EULA) and about GCS itself as well as log out. If you’re not logged in, you still have access to this screen.

...

6️⃣ Use the radio buttons on the left to toggle between other options. See the sections below for more information.

If your ETU is not connected, you’re still able to access Preview mode. Go to New Device 8️⃣7️⃣.

...

Choose the ETU you want to check out 9️⃣8️⃣.

...

You can now explore the functionalities with a connected ETU or without.

...

Once you log in, you’re taken to the Dashboard, which contains 1️⃣ information about the App version and your operating system info as well as 2️⃣ the board version, edition, serial number, and firmware version of the connected TITAN. 3️⃣ Here you can update your unit to the latest firmware version and/or 4️⃣ upgrade the edition to ADVANCED or EXPERT.

Click the mail icon to in the upper right corner to go to messages 5️⃣.

Image Removed

Use the radio buttons on the left 6️⃣ to toggle between other options. See the sections below for more information tap + 1️⃣ to connect 2️⃣ your devices choosing them from the list below and providing PIN numbers where necessary or go to Preview Mode 3️⃣ to explore the features without connecting .

...

Once you have connected all the devices you need, your Dashboard looks like this:

...

  • tap the left arrow to go to the Main Menu (more below)

  • activate Shooting Mode

  • go to the GCS Search feature

Tap the GATE Control Station icon 2️⃣ to reveal information about your:

  • Device model

  • Operating system

  • GCS App Version

Below you will see other connected devices such as STATUS 3️⃣, Blu-Link 4️⃣, and ETU 5️⃣. Tap each one of them to go their Main Menu, where you will find relevant radio buttons revealing more details. The example below shows TITAN V2.

If you’re logged in, in the top left corner you will see your nick 7️⃣ 6️⃣ next to the GATE logo. Click it and you’re taken to the Preferences screen, where you can check and/or update your account info and privacy settings, submit feedback, get help, read the End User Licence Agreement (EULA) and about GCS itself as well as log out. If you’re not logged in, you still have access to this screen.

...

If your ETU is not connected, you’re able to access Preview mode. Go to New Device 8️⃣.

...

Choose the ETU you want to check out 9️⃣.

...

You will also be able to access your inbox.

Below the GATE logo you will find a dropdown list containing other connected devices 7️⃣. Tapping any of them will take you to their Main Menu containing relevant radio buttons.

Tap This Device 8️⃣ to reveal:

  • Firmware Edition

  • Serial Number

  • Firmware Version

  • Upgrade to ADVANCED or EXPERT

...

You can now explore the functionalities with a connected ETU or without.

...

General

...

Click here 1️⃣ to go to Restore Default Settings 2️⃣ – restores default settings for the various functionalities. Trigger and Selector calibration as well as Telemetry data remain unchanged and 3️⃣ Restore Factory Settings – (hard reset) restores all default settings, resets your Telemetry, and clears adaptation data.

4️⃣ 3️⃣ Cycle Detection – switches ON or OFF the optical gear sensor. Cycle Detection OFF can be compared to an emergency mode for problems with the gear sensor. Most TITAN features will be disabled, but you can still shoot in AUTO.

5️⃣ 4️⃣ Thanks to the Gear sensor, TITAN precisely detects in which position the cycle should finish. Therefore, even the shortest Trigger action produces at least one full cycle.

6️⃣ 5️⃣ A set of preferences referring to the active profile and switching between Profiles.

7️⃣ 6️⃣ Battery protection – modern LiPo and LiFe batteries are very sensitive to overdischarge. The microprocessor monitors the battery voltage constantly. When the voltage drops down to a critical level, it will not allow firing. Battery cell – when the battery voltage drops to the specified level (in relation to one cell), the motor will vibrate. Available settings: OFF, 3.1 V, 3.2 V, 3.3 V or 3.4 V per cell for LiPo batteries and 2.6 V, 2.7 V, 2.8 V or 2.9V per cell for LiFe batteries.

8️⃣ 7️⃣ Series Safety Limit – enables to set a predefined number of BBs fired in a single series. It can be used as a protection against Trigger jam. In case of emergency, you can stop the series by switching the Selector position.

9️⃣ 8️⃣ Gear Ratio - to activate Pre-Cocking with the highest level of precision you should define the gear type in your AEG; available types: Normal Speed, Low Speed, High Speed, DSG, 19-Tooth.
Typical gear ratio settings (excluding DSG and 19-tooth):
Low Speed: <15 RPS
Normal Speed: 15-25 RPS
High Speed: >25 RPS
If overspin occurs, you should switch the gear type to the next one (e.g. Normal Speed to Low Speed).

...

Tip

Note
The regional lock designed for German players will disable all the BURST and AUTO options.

Trigger

...

1️⃣ Use Trigger Preferences to calibrate your trigger. You can only make changes once you've connected your replica with an ETU inside. You will learn more about TITAN trigger calibration here: Information for Use (In4U) [TTN]

...

2️⃣ Pre-Cocking allows for initial spring compression, which speeds up Trigger response significantly:
Auto – the spring is automatically compressed after each shot. In Auto you can also set Boost, which determines the strength of spring compression. The highest setting results in the best Trigger response, but also mostly increases wear and tear on the gearbox.
If overspin occurs, set Gear Ratio to High Speed.

...

.

Manual – you can set the custom values on SEMI, BURST, and AUTO.screen

...

Note

Caution
The highest setting results in the best Trigger response, but also greatly increases wear and tear on the gearbox.

3️⃣ ROF Control enables a reduction in a gun’s Rate of Fire. You can use stronger LiPo batteries, and still have a ROF just like in a real gun. ON – . ROF control enables the reduction of a gun’s Rate of Fire. You can use stronger batteries and still have an ROF exactly as you like. Depending on Firmware edition, you can choose from among the following settings:

  • Off

  • Adaptive ROF control allows you to set the target Rate of Fire in rounds per second.

  • Manual PWM uses Pulse-Width Modulation to decrease ROF.

  • Manual Delay adds breaks between shots to decrease ROF.

  • Manual Delay + PWM combines Pulse-Width Modulation and breaks between shots.

...

ROF Control uses PWM (Pulse Width Modulation) to decrease ROF. Thanks to this, the gearbox works smoothly, which decreases wear and tear of AEG internal parts. The percentage value determines the PWM duty cycle and it does not reflect ROF decrease.OFF – ROF Control adds breaks between shots to decrease ROF, which gives you a more realistic experience. This option set to 50% will significantly reduce ROF.

4️⃣ You don't need to fully release the Trigger to fire the next shot. This option is really useful when the Trigger sensitivity level is very high. Choose between two types of Equalizer:

...

1LVL, 2LVL and MANUAL are especially useful when trigger sensitivity level is very high, so you do not need to fully release the trigger while firing quickly:

...

5️⃣ Sniper Delay lets you to set delay between each SEMI shot to simulate the delay from reload or recoil. You can set it between 0.01 and 5 s. By choosing the Manual with Vibration option, you can enable a vibration which will inform you when the gun is ready to fire again.

...

Selector

...

1️⃣ Selector mode Mode – allows you to choose how your replica will behave behaves in each Selector position:
Depending on Firmware Edition, you can set 1 of the 7 options in each Selector position.

...

SAFE – the replica will not fire when the Trigger is pulled
SEMI – one pull of the Trigger will result in only one shot
BURST – one pull of the Trigger enables you to shoot a pre-determined number of BBs, which is very useful in MILSIM MilSim and when using low-caps
AUTO – pulling the Trigger causes fires an uninterrupted* series of shots until the Trigger is released
*the series can be limited by the Round Limit.

Besides the SAFE, SEMI, AUTO, and BURST modes, there is the BINARY Trigger — a single BB is fired when the Trigger is pressed and another one when the Trigger is released; SEMI Ramping – quickly squeezing the Trigger turns on AUTO mode; BURST/AUTO – pulling the Trigger quickly sets BURST and holding it down sets AUTO.

2️⃣ Burst Mode – sets the exact number of BBs fired in a single BURST. Interruptible allows you to stop the BURST by releasing the Trigger. Full will fire the exact number of BBs without stopping even if the Trigger is released during the BURST. In case of emergency, you can stop the series by switching the Selector position.

...

Magazine

1️⃣ Magazine Mode – allows to switch on Magazine Simulation and Bolt Catch in NGRS gearboxes.

2️⃣ Magazine Capacity – depending on the Firmware Edition, allows you to set magazine capacity simulation from 1 BB up to 250 BBs. Please note that in all gearboxes except NGRS, all the BBs fired are counted until the counter reaches the set capacity, even if the real magazine is replaced in the middle of magazine simulation. In NGRS gearboxes, thanks to the magazine sensor, if the real magazine is replaced during magazine simulation, the counter is reset to the full simulated magazine capacity. In all cases, you are informed about an empty simulated magazine with vibrations — a high one and two low ones.

3️⃣ Reload Time – depending on the Firmware Edition, enables you to set the exact time of simulated magazine replacement from 0.1 s up to 10.0 s. During this time you will not be able to shoot.

4️⃣ Low Ammo Warning – enables you to set the exact number of BBs fired before low ammo warning vibrations – a high one and a low one.

...

Alerts

...

1️⃣ Vibration Notifications – allows you to select the type of notifications you will be informed about with vibrations.

...

Telemetry

Telemetry contains main information about your replica’s performance. You can simply clear each value by clicking the Reset button. You can also independently reset BB1 and BB2 counter.
TITAN gives you the option to check:
ROF - Minimum, Average, Maximum
Trigger response - Minimum, Average, Maximum
Module temperature - Minimum, At this moment, Maximum
Motor current - Average AUTO, Average SEMI, Maximum Peak
Battery voltage - Minimum, Last, Maximum
Number of fired BBs - BB1, BB2, TOTAL

...

This TAB will help you to troubleshoot your replica in case of any issue. If you need additional help, you can contact our Support Center using  “SEND REPORT” button, or save the report using  “SAVE TO FILE” button.

...


If an error occurs, it will be  highlighted and  described. In such a case, we suggest to follow  ”WHAT TO DO” instructions in the first place.

Instructions

 

...

Powiązane artykuły

Filter by label (Content by label)
showLabelsfalse
max5
spacescom.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@a32
sortmodified
showSpacefalse
reversetrue
typepage
cqllabel = "kb-how-to-article" and type = "page" and space = "RD"
labelskb-how-to-article

...

hiddentrue

...