The most common mistakes:
1. Washer Issue
User's fault: placing washers in wrong order
Result: short circuit and permanent damage to TITAN
How to detect?:
Correct order:
...
2. Trigger Sensor Damage
User's fault: pulling the trigger when the gearbox is open
Result: torn off trigger sensors
TITAN will not be able to detect all 5 trigger sensitivities even if using a standard trigger (please note that in the case of speed triggers TITAN cannot detect all trigger sensitivities either, which does not mean that sensors are damaged).How to detect?: missing trigger sensors (receivers)
...
3. Cable Damage
User's fault: incorrect cable routing
Result: damaged or torn off wires by motor gear
How to detect?: damaged insulation
...
4. Capacitor Damage
User's fault: mounting TITAN V2 in an ICS gearbox without necessary modifications
Result: the gearbox latch has damaged or torn the yellow capacitor
How to detect?: yellow capacitor is missing or damaged
...
5. Gear Sensor Damage
User's fault: very low sector gear shimming
Result: torn off gear sensor
How to detect?: missing gear sensor
...
Less frequently encountered:
6. Fire Selector Sensor Damage
User's fault: incorrect bottom board placement in gearbox shell
Result: torn off Fire Selector sensor
How to detect? : one of the trigger sensors missing
7. Motor connector damage
User's fault: using too much force during motor connector bending, bending connectors wrong way
Result: broken motor connector
How to detect? : motor connector broken in half
8. Reverse polarity
User's fault: plugging a battery into the unit in incorrect order (a negative wire with a positive wire and a positive wire with a negative wire)
Result: destroying the main parts of the board
How to detect? : theunit is not responding, the entire board is burnt
...
9. Wire Damage (Caused by Trigger)
User's fault: incorrect wire placement in gearbox shell
Result: torn wire insulation
How to detect? : tornwire insulation close to the trigger
10. Short Circuit Caused by Damaging Cable Insulation
User's fault: accidentallycutting both positive and negative wires with the body of the replica
Result: Insulation damage, short circuit
How to detect? : visibly cut wires
11. Repairs or Structural Modification of any TITAN Part (including rewiring and component replacement)
User's fault: interference in the structure of the unit
Result: automatic warranty loss
How to detect? : visible changes such as different wire color
...
Other Cases When Warranty May Be Accepted:
Recurring E01 to E06, E13, E14, and E15 errors
No reaction whatsoever from the unit without visible damage
No connection with USB-Link and/or Tactical Programming Card even if the unit is working properly without any visible damage (no programming option)
Recurrence of error E07 combined with no cycle detection (after detailed troubleshooting)
Info |
---|
In case of any doubts please contact our Support at:Typical response time is up 2 business days |
Related articles
Filter by label (Content by label) | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
...