TITAN V2 – ver. 3.0-04
Release date: 29-04-2020
Improved:
Algorithm of supply voltage sensor
TITAN V2 – ver. 3.0-03
Release date: 16-03-2020
Improved:
Clearing of all statistics in case of factory settings reset
Operation of ‘ROF achieved on Semi’ statistic
DSG algorithm
Other bug fixes
Changed:
In programming via trigger mode, vibration indicating an option/function occurs only after releasing the trigger
TITAN V2 – ver. 3.0-01
Release date: 08-11-2019
Release of beta GBU and EXPERT firmware:
TITAN V2 – ver. 2.2b05
Release date: 01-08-2018
Added:
Possibility to turn off switching of pre-cocking mode via fire selector
TITAN V2 – ver. 2.1
Release date: 08-11-2017
Added:
Possibility to adjust motor braking power
TITAN V2 – ver. 2.0
Release date: 27-07-2017
Added:
Statistics
Rankings
Compatiblility with 19-tooth sector gear
Regional lock
Improved:
Pre-cocking setup via fire selector. Now you don't need to fire a shot to switch pre-cocking mode. You can do it in two ways:
a) Switch fire selector to SAFE and pull the trigger
b) Switch fire selector to SEMI, fire a shot and keep the trigger pulled
While the trigger is being pulled, you are able to select pre-cocking mode:
SAFE = Pre-cocking OFF
SEMI = Pre-cocking SMART
AUTO = Pre-cocking AUTO
Motor emergency shutdown with fire selector. It is possible only when switching from AUTO to SAFE. Switching fire selector between SEMI <–> AUTO or SEMI <–> SAFE during a shot does not induce any break of cycle or vibration.
Low battery warnings. User is warned 5 times before the battery is discharged. Each warning is communicated by 3 vibrations: HIGH → MID → HIGH.
Changed:
Mode of notifying user about discharged battery (UVP1). Now these are 3 vibrations: HIGH → MID → LOW.
TITAN V2 – ver. 1.9
Release date: 21-02-2017
Added:
Trigger equalizer configuration (OFF, EQ1, EQ2).
OFF – to fire a next shot, you need to release the trigger until it reaches the selected trigger sensitivity level
EQ1 – to fire a next shot, just release the trigger so as it changes the state of two trigger sensors
EQ2 – to fire a next shot, just release the trigger so as it changes the state of one trigger sensor
EQ1 or EQ2 are especially useful when trigger sensitivity level is very high. Then you don't need to fully release the trigger while quickly firing on SEMI.
Fire selector sensors calibration (via GCS). Your selector will work even more precisely
Option to turn off the motor by switching fire selector when cycle detection is OFF.
Improved:
UVP2 protection – a new power supply algorithm. You can shoot more BBs with the same battery. Now TITAN works much more efficiently with weak, low capacity batteries (also NiMH and NiCd).
Trigger detection algorithm
Pre-cocking SMART
ROF stabilization
Self-test for voltage higher than 16.5V
TITAN V2 – ver. 1.8
Release date: 06-12-2016
Improved:
Trigger detection. Added compatibility with speed triggers and triggers with hole. Fixed problem with double shooting during trigger release.
Diagnostic Trouble Codes detection
Add Comment