Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

« Previous Version 17 Next »

v4.0-01 [2022-08-24]

BASIC, ADVANCED and EXPERT

Improved:

  • SAFE / SEMI / BINARY instead of SAFE / BINARY / AUTO selector mode

  • trigger sensor functionality: new noise-resistant trigger detection algorithm

  • new Programming via Trigger card available at https://help.gatee.eu/

Added:

  • brushless motor support

  • brushless motor configuration without connecting to GCS

  • trigger sensitivity adjustment without connecting to GCS

  • pre-cocking boost adjustment without connecting to GCS

  • automatical pre-cocking: LOW / MID / HIGH

  • service mode that allows you to check the operation of the gear sensor during installation without using GCS

BASIC

Added:

  • new Magazine Capacity option: 115 BBs

  • new Reload time option: 0.5 s

  • new Low ammo warning option: 10 BBs

  • new Sniper delay option: 0.2 s/0.5 s

  • new Cycle detection mode: Manual

ADVANCED

Added:

  • new Low ammo warning option: 20 BBs

  • new Adaptive ROF Control mode: 1/2/3/...100 RPS

  • new Cycle detection mode: Manual


v3.5-02 [2021-08-09]

Added:
- communication with STATUS
Removed:
- Programming via Trigger
Improved:
- sending selector state to STATUS

v3.2-02 [2020-09-08]

Improved:
- 2-stage trigger operation for Quantum Trigger
- Fire selector operation at high ambient temperatures
Fixed:
- Elimination of a shot while switching from SAFE to SEMI when Quantum Trigger is pressed

v3.2 [2020-07-21]

Improved:
- DTC error tracking if the trigger and/or selector
- gear sensor support for GCS
- other improvements

v3.1 [2020-07-01]

Fixed:
- First shot failure after switching fire selector from SAFE

Added:
- Green LED blinks after connecting the battery if self test was passed successfully

v3.0-80 [2022-04-25]

Improved:
- Operation of the trigger
- Detecting of 2-cell battery
- Removing of blockade after trigger sensor was overexposed
- First shot failure after switching fire selector from SAFE
- 2-stage trigger operation for Quantum Trigger
- Fire selector operation at high ambient temperatures
- DTC error tracking if the trigger and/or selector
- Gear sensor support for GCS

Other improvements
Fixed:
- Elimination of a shot while switching from SAFE to SEMI when Quantum Trigger is pressed
Added:
- Support for BLDC motors
- Support for GATE Quantum Triggerâ„¢
- Green LED blinks after connecting the battery if self test was passed successfully

v3.0 [2019-11-20]

Improved:
- Calibration of device without using GCS
- Various improvements enhancing operation of the device

  • No labels

0 Comments

You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.