v4.x

BASIC, ADVANCED and EXPERT

Improved:

  • SAFE / SEMI / BINARY instead of SAFE / BINARY / AUTO selector mode

 

Added:

  • brushless motor support

  • brushless motor configuration via GCS

 

BASIC

Added:

  • full access to Telemetry data previously available only with EXPERT firmware

  • new pre-cocking options: LOW / HIGH

  • new Magazine Capacity option: 115 BBs

  • new Reload time option: 0.5 s

  • new Low ammo warning option: 10 BBs

  • new Sniper delay option: 0.2 s/0.5 s

  • new Cycle detection mode: Manual

 

ADVANCED

Added:

  • full access to Telemetry data previously available only with EXPERT firmware

  • new Low ammo warning option: 20 BBs

  • new Adaptive ROF Control mode: 1/2/3/...100 RPS

  • new Cycle detection mode: Manual

v3.6-05 (03-06-2022)

Improved:
- Communication between the ETU and STT/Virtual STT (Blu-Link version 1.2-11 or later required)
- Operation of the reset bolt catch function (Blu-Link version 1.2-11 or later required)

v3.5-02

Improved:
- ROF Binary Trigger
- Dynamic Communication functioning

v3.5-01

Added:
- communication with STATUS
Removed:
- Programming via Trigger

v3.0-04

Improved:
- algorithm of supply voltage sensor

v3.0-03

Improved:
- Clearing of all statistics in case of factory settings reset
- Operation of ‘ROF achieved on Semi’ statistic
- DSG algorithm
- Other bug fixes
Changed:
- In programming via trigger mode, vibration indicating an option/function occurs only after releasing the trigger

v3.0-01

Release of beta GBU and EXPERT firmware

details

v2.2b05

Added:
- Possibility to turn off switching of pre-cocking mode via fire selector

v2.1

Added:
Possibility to adjust motor braking power

v2.0

Added:
- Statistics
- Rankings
- Compatiblility with 19-tooth sector gear
- Regional lock
Improved:
- Pre-cocking setup via fire selector. Now you don't need to fire a shot to switch pre-cocking mode. You can do it in two ways:
a) Switch fire selector to SAFE and pull the trigger
b) Switch fire selector to SEMI, fire a shot and keep the trigger pulledWhile the trigger is being pulled, you are able to select pre-cocking mode:SAFE = Pre-cocking OFFSEMI = Pre-cocking SMARTAUTO = Pre-cocking AUTO
- Motor emergency shutdown with fire selector. It is possible only when switching from AUTO to SAFE. Switching fire selector between SEMI <–> AUTO or SEMI <–> SAFE during a shot does not induce any break of cycle or vibration.
- Low battery warnings. User is warned 5 times before the battery is discharged. Each warning is communicated by 3 vibrations: HIGH → MID → HIGH.
Changed:
- Mode of notifying user about discharged battery (UVP1). Now these are 3 vibrations: HIGH → MID → LOW.

v1.9

Added:
- Trigger equalizer configuration (OFF, EQ1, EQ2).
OFF – to fire a next shot, you need to release the trigger until it reaches the selected trigger sensitivity level 
EQ1 – to fire a next shot, just release the trigger so as it changes the state of two trigger sensors
EQ2 – to fire a next shot, just release the trigger so as it changes the state of one trigger sensor
EQ1 or EQ2 are especially useful when trigger sensitivity level is very high. Then you don't need to fully release the trigger while quickly firing on SEMI.
- Fire selector sensors calibration (via GCS). Your selector will work even more precisely
- Option to turn off the motor by switching fire selector when cycle detection is OFF.
Improved:
- UVP2 protection – a new power supply algorithm. You can shoot more BBs with the same battery. Now TITAN works much more efficiently with weak, low capacity batteries (also NiMH and NiCd).
- Trigger detection algorithm
- Pre-cocking SMART
- ROF stabilization
- Self-test for voltage higher than 16.5V

v1.8

Improved:
- Trigger detection. Added compatibility with speed triggers and triggers with hole. Fixed problem with double shooting during trigger release.
- Diagnostic Trouble Codes detection