Table of Contents |
---|
Lea atentamente antes de usar. Guárdelo para referencia futura.
Info |
---|
¡No leer esta información puede anular la garantía! |
La información contenida en este documento sujeta a cambios sin previo aviso por cambios en las especificaciones u otras razones. Cuando utilice un producto de la lista aquí, asegúrese de obtener las especificaciones más recientes.
Instalación
Note |
---|
Precaución |
Note |
---|
Precaución |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
Nota
|
ASTER V2
Note |
---|
Precaución |
Note |
---|
Precaución |
Note |
---|
Precaución |
Note |
---|
Precaución |
Note |
---|
Precaución |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
Nota |
Note |
---|
Precaución |
Quantum Trigger
Tip |
---|
Nota |
Tip |
---|
Nota |
Note |
---|
Precaución |
Note |
---|
Precaución |
Note |
---|
Precaución |
Tip |
---|
Nota |
ASTER V3
Note |
---|
Precaución |
Note |
---|
Precaución |
Note |
---|
Precaución |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
Nota |
Tip |
---|
|
Note |
---|
Precaución |
Calibration
Tip |
---|
Nota |
Tip |
---|
Nota |
Once ASTER is installed in an AEG, the trigger and selector sensors must be calibrated according to the steps below:
ASTER V2
If your ASTER is brand new, go to step 2. If not, restore factory settings as described in
Restoring Factory Settings below and then go to step 2.
To calibrate ASTER, plug in the battery. You will hear 3 low frequency vibrations indicating lack of calibration error.
Switch the selector to AUTO. While in AUTO, pull the trigger twice and wait for a confirmation vibration.
Then, switch the selector to SEMI. While in SEMI, pull the trigger once and wait for a confirmation vibration.
Next, switch the selector to SAFE. While in SAFE, wait for a confirmation vibration. Now ASTER is fully calibrated and ready to use.*
*If there is a problem during calibration, you will hear a short high and mid frequency vibration. Then, calibrate the selector again.
ASTER V3 (AK Selector Type)
If your ASTER is brand new, go to step 2. If not, restore factory settings as described in
Restoring Factory Settings below and then go to step 2.
To calibrate ASTER, plug in the battery. You will hear 3 low frequency vibrations indicating lack of calibration error.
Switch the selector to AUTO.
Pull the trigger once and wait for a confirmation vibration.
Switch the selector to SEMI.
Pull the trigger once and wait for a confirmation vibration.
Switch the selector to AUTO again.
Pull the trigger once and wait for a confirmation vibration.
Switch the selector to SAFE.
10. Wait for a confirmation vibration. Now ASTER is fully calibrated and ready to use.*
*If there is a problem during calibration, you will hear a short high and mid frequency vibration. Then, calibrate the selector again.
G36 Selector Type
If your ASTER is brand new, go to step 2. If not, restore factory settings as described in the corresponding chapter (page 60) and then
go to step 2.
To calibrate ASTER, plug the battery. You will hear 3 low frequency vibrations notifying lack of calibration error.
Switch fire selector to SEMI.
Pull the trigger twice and wait for a confirmation vibration.
Switch fire selector to AUTO.
Pull the trigger once and wait for a confirmation vibration.
Switch fire selector to SEMI again.
Pull the trigger once and wait for a confirmation vibration.
Switch the selector to SAFE.
10. Wait for a confirmation vibration. Now ASTER is fully calibrated and ready to use.*
If there is a problem during calibration, a short high and mid frequency vibration occurs. Then, calibrate the selector again.
Tip |
---|
Nota |
Quick Access Menu
You can access Pre-Cocking or Profiles using a shortcut. After firing a shot, burst or while in SAFE (only if the safety lever has been removed)*, hold the trigger and switch the selector within the specified time (see table). Switch the selector in any order to change between the options indicated by motor vibrations.
By releasing the trigger, you exit the function confirming it. Bear in mind that Programming via Trigger is a different process. To find out more check the PROGRAMMING VIA TRIGGER CARD included or continue reading below.
*You can enter Programming via Trigger only when the selector on the replica is in SEMI position and AUTO mode is not assigned to this position.
| Function | ||||
| available if preset in GCS | in SEMI or BURST mode preset in GCS in SEMI physical position only | |||
| Pre-Cocking | Profiles (EXPERT only) | Programming via trigger | ||
To enter the function: hold the trigger | and switch the selector within 2 s | and switch the selector within 2-7 s | for > 7 s | ||
Available options | Option | Low frequency vibration | Option | High frequency vibration | check the PROGRAMMING VIA TRIGGER CARD included or continue reading below |
Off | 1 | Profile 1 | 1 | ||
On | 2 | Profile 2 | 2 | ||
Profile 3 | 3 |
Pre-Cocking
In GCS go to Trigger>Pre-Cocking>Switch Mode via Selector and use the toggle button to activate this function.
Fire a shot, burst or pull the trigger while in SAFE mode (only if the safety lever has been removed) and do not release the trigger.
Switch the selector within 2 s. There is a single low frequency vibration.
Switch the selector in any order to change between the options indicated by vibrations:
1 low frequency vibration – Pre-cocking Off
2 low frequency vibrations – Pre-cocking On
Release the trigger to save selected mode
Profile Selection
Profiles are sets of particular settings of configurable ASTER functions. You can choose one of the three profiles at a time. Go to General>Profiles>Change Profile via Selector in GCS to be able to use this function. If you want to change the active profile:
Fire a shot, burst or pull the trigger while in SAFE (only if the safety lever has been removed) and do not release the trigger.
Switch the selector within 2–7 s. There is a single high frequency vibration.
Switch the selector in any order to change between options, which are indicated by vibrations.
1 high frequency vibration – Profile 1
2 high frequency vibrations – Profile 2
3 high frequency vibrations – Profile 3
Release the trigger to save the selected profile.
Programming via Trigger
This programming mode allows you to set the options of basic ASTER functions.
Tip |
---|
Nota |
Turning on Programming Mode
Switch the selector on your replica to SEMI or BURST.* If AUTO mode is selected in SEMI position, use the alternative method below.
Fire a shot or burst and do not release the trigger.
Hold the trigger for 7 seconds – until you hear a vibration and see dark blue light in the trigger hole
*Not possible if AUTO mode is selected in SEMI position
Alternative Method
Disconnect the battery
Switch the selector position to SEMI
Pull the trigger and do not release it
Connect the battery (ignore the warning vibrations)
Hold the trigger for 3 s – until you hear a vibration and see dark blue light in the trigger hole
You can easily change the menu level by switching the selector. Pull the trigger to quickly navigate the menu. Each time you pull the trigger, the LED color changes as well as the number of accompanying vibrations. The table presents functions and their options programmable via trigger as well as how they are indicated by LED and vibrations.
Tip |
---|
Nota |
grafika pokazująca co oznacza dana pozycja selektora, gdzie znajduje się LED, oraz jak działa spust w zależności od długości kliku*
Tip |
---|
Nota |
*To execute an action from Advanced, hold the trigger down for more than 3 seconds.
**This needs to be predefined in the GCS and is then available at trigger level. Once you disconnect the battery, the setting cannot be changed and needs to be reintroduced in GCS.
Selecting a Function
Switch the selector to SEMI.
To get to a function, pull the trigger the specified number of times (according to the table above).
Selecting an Option of a Function
Switch the selector to AUTO.
To get to an option of a selected function, pull the trigger the specified number of times (according to the table above).
Saving an Option
To save an option, switch the selector to SEMI.
The setting is saved and you are back to the functions menu.
You can set the options of the other basic functions the same way.
Advanced Options
Select the Advanced option.
Pull and hold the trigger for more than 3 seconds.
Exiting the Programming Mode
Switch the selector to SAFE.
Enjoy the ASTER functions you've just set.
Activating SAFE Mode if Not Assigned
If SAFE mode is not assigned in GCS, it is possible to activate it via the selector*:
Switch the selector rapidly in this sequence: SAFE → SEMI → SAFE (SAFE → AUTO → SAFE for AK-47).
Now SAFE mode is activated – switch to SEMI or AUTO to deactivate it.
Switching to SAFE again accesses the fire mode assigned to the SAFE position in the GCS.
*SAFE mode also applies when the selector is in SAFE while connecting the battery – switching to SEMI or AUTO deactivates it.
Tip |
---|
Nota |
Programming via USB-Link
Tip |
---|
Nota |
Note |
---|
Precaución |
Note |
---|
Precaución |
Connect the USB-Link via its Micro-USB plug to your PC, Mac or smartphone using one of the dedicated USB cables:
USB-A cable for PC/Mac
Micro-USB or USB-C cable for smartphones
Tip |
---|
Nota |
Tip |
---|
Nota |
Connect ASTER to the USB-Link.
Tip |
---|
Nota
|
Now you can control ASTER via GCS.
USB-Link Troubleshooting
USB-Link has a 4-color LED indicator.
BLUE (glowing)
The USB-Link is connected to PC or smartphone. ASTER is not connected or PC driver is not installed. You can download the driver here: http://www.gatee.eu/drivers .
BLUE (blinking)
The USB-Link does not have firmware installed. Please install the firmware.
GREEN (glowing)
The USB-Link is connected to ASTER and PC, Mac or smartphone.
GREEN (blinking)
The USB-Link is connected to ASTER and PC, Mac or smartphone, but ASTER does not have firmware installed. Please install the ASTER firmware.
YELLOW (glowing)
The USB-Link is transmitting data.
RED (glowing)
Communication with ASTER was interrupted while saving settings. ASTER settings may have been transmitted incorrectly. Please check the connection between the USB-Link and ASTER.
Restoring Factory Settings
Tip |
---|
Nota |
Tip |
---|
Nota |
You can restore Factory Settings in 3 ways:
Via GCS:
Go to General. Open the menu in the upper right corner and select Restore factory settings.
While in programming mode:
Turn on the programming mode as described in Programming via Trigger
Switch the selector to SEMI
Pull the trigger 4 times to select Advanced (5 vibrations, LED glowing orange)
Switch the selector to AUTO
Pull the trigger to get to Restore Factory Settings (4 vibrations, LED glowing pink)
Confirm the Restore Factory Settings option by pulling the trigger for at least 3 seconds
While connecting the battery:
Disconnect the battery
Pull the trigger
While the trigger is pulled, connect the battery (ignore the warning vibrations)
Hold the trigger for 10 seconds until you hear 2 vibrations confirming the reset (ignore the vibrations occurring in the meantime informing about entering the programming mode)
Release the trigger
Tip |
---|
Nota |
Troubleshooting
Low Battery Warnings
When activated, you are warned 5 times before the battery is discharged. Each warning is communicated by 3 vibrations: High → Mid → High.
Vibrations after connecting the battery
ASTER can detect number of battery cells automatically. If you activate this function, vibrations start once the battery is connected. Remember to always check if ASTER detected correct number of battery cells.
Vibrations after connecting the battery | Explanation |
1 short high frequency | Cell detection error |
2 short high frequency | Two cells detected |
3 short high frequency | Three cells detected |
4 short high, 1 long low frequency | The voltage is too high |
3 short low frequency | Lack of trigger or selector calibration |
4 short low frequency | Trigger error: after connecting the battery, ASTER detected a trigger position where a shot may be fired |
Diagnostic Trouble Codes
Diagnostic Trouble Codes (DTC) enable detecting basic malfunctions and problems with your AEG or ASTER. You are notified of the main errors with LED lights glowing in the trigger hole and vibrations. These light-and-sound sequences are activated once a malfunction takes place. DTCs can be later read and cleared in the DTC menu in GCS as well as in the Programming Mode in Advanced Settings. In the latter case, the LED light blinks the same number of times as the motor vibrates, so you can check DTCs even without a connected motor.
If DTCs are read while in Programming Mode:
The LED light in the trigger hole glows in the color reflecting the issue type
Yellow indicates a warning
Red indicates a problem
Red-Blue blinking alternately indicates the device failed on self-test
Red-Yellow blinking alternately indicates other errors
Each vibration type corresponds to an issue type
high frequency vibrations indicate a warning
low frequency vibrations indicate a problem
Low-high frequency vibrations indicate the device failed on self-test
High-low frequency vibrations indicate other errors
The number of vibrations determines exactly what the problem is (for reference read the DTC explanations presented later on in this guide)
Tip |
---|
Nota |
The table presents DTC along with their possible reasons and solutions.
DTC name | DTC | LED indicator color / number of blinks and vibrations / vibration type | Error description (what happened) | Possible reason (why it happened) | Possible solution (what to do) |
No errors | Green / 1 / - | No errors detected | Everything is fine | Enjoy airsofting | |
Under Voltage Protection 1 | UVP1 | Yellow / 1 / High | Protection against over-discharge of the battery. Battery protection was activated. |
|
|
Under Voltage Protection 2 | UVP2 | Yellow / 2 / High | The voltage dropped below 1.9 V which is critical for ASTER to work properly. |
|
|
Under Voltage Protection 3 | UVP3 | Yellow / 3 / High | Protection against over-discharge of the battery. Battery protection was activated immediately after connecting the battery. |
|
|
Motor Disc | MOTOR DISC | Yellow / 4 / High | ASTER did not detect the motor. |
|
|
Gear Not Detected | GND | Red / 1 / Low | ASTER did not detect the sector gear. |
|
set Cycle detection to Off |
Overload | OVL | Red / 2 / Low | Too high load. The load limit was exceeded. |
|
|
Over Current Protection | OCP | Red / 3 / Low | ASTER detected too high current. Overcurrent protection was activated. |
|
|
Short Circuit Protection | SCP | Red / 4 / Low | ASTER detected current over 220 A. Short circuit protection was activated. |
|
|
Over Temperature Protection | OTP | Red / 5 / Low | ASTER temperature is too high. Over temperature protection was activated. |
|
|
Self-test Failure | STF | Red-Blue / 2 / Low-High | The device failed on self-test. |
|
|
Other error | Red-Yellow / 2 / High-Low | Connect ASTER with GCS and check DTC |
Tip |
---|
Nota
|